Fachartikel in der Zeitschrift Journal of Endodontics, 2024-09. Verfasst von Stefani Jovedi Rosa und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Operative Dentistry, Endodontics, and Dental Materials, Bauru School of Dentistry, University of São Paulo - USP, Bauru, Brazil. Hauptthemen laut MEDLINE: Root Canal Filling Materials, Epoxy Resins, Materials Testing. Die Arbeit wurde bisher 14-mal zitiert (Crossref) und nennt 33 Literaturangaben. Gefördert von: Conselho Nacional de Desenvolvimento Científico e Tecnológico.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

INTRODUCTION: The purpose of this study was to evaluate whether the mixing method of AH Plus Jet sealer affects its physicochemical and mechanical properties. METHODS: The properties of AH Plus Jet sealer were analyzed when mixed using either the Auto Mix Tip or manual mixing. The evaluated properties included radiopacity (n = 5), initial and final setting times (n = 5), flow (n = 5), and solubility (n = 3), following specifications outlined in ISO 6876/2012 and ADA Nº 57/2000. pH levels were measured at intervals of 3, 24, 72, and 168 hours (n = 10). The push-out bond strength test was conducted using a universal testing machine and using bovine teeth (n = 30). Failure modes were analyzed with stereomicroscopy. Porosity was evaluated under micro-CT (n = 5), and scanning electron microscopy was also performed (n = 5). One-way analysis of variance and Tukey, unpaired t-tests, or Mann-Whitney tests were used with a significance level of 5%. RESULTS: The Auto Mix exhibited a radiopacity value of 12.11 mmAl, whereas manual mixing resulted in 12.55 mmAl (P > .05). For initial and final setting times, Auto Mix showed 901 minutes and 1779 minutes, respectively, while manual mixing recorded values of 631 minutes and 1504 minutes (P .05). Manual mixing presented a higher bond strength value (14.52 MPa) than Auto Mix (9.81 MPa) (P < .05). The mixed failure mode was the most frequent outcome for both methods. The highest porosity was observed for Auto Mix (P < .05). Scanning electron microscopy analysis revealed that manual mixing resulted in a smoother surface with fewer pores and smaller, more evenly distributed agglomerates compared to automatic mixing. CONCLUSION: The mixing method employed for AH Plus Jet sealer influences some physicochemical and mechanical properties of the material.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Root Canal Filling MaterialsEpoxy ResinsMaterials TestingCattleAnimalsMicroscopy, Electron, ScanningSolubilityHydrogen-Ion Concentration

Stichwörter der Autor:innen

AH Plusendodonticsepoxy resinphysicochemical propertiespush-out bond strengthroot canal sealer

Substanzen

Root Canal Filling MaterialsEpoxy Resinsepoxy resin-based root canal sealer

Autor:innen und Institutionen

  • Department of Operative Dentistry, Endodontics, and Dental Materials, Bauru School of Dentistry, University of São Paulo - USP, Bauru, Brazil.
  • Department of Endodontics, School of Dentistry, Grande Rio University (UNIGRANRIO), Rio de Janeiro, Brazil.
  • Department of Dentistry, Fortaleza Federal University (UFCE), Sobral, Brazil.
  • Department of Operative Dentistry, Endodontics, and Dental Materials, Bauru School of Dentistry, University of São Paulo - USP, Bauru, Brazil. Electronic address: murilo_alcalde@hotmail.com.

Förderung

  • Conselho Nacional de Desenvolvimento Científico e Tecnológico

Zitieren

APA

Rosa, S. J., Duarte, M. A. H., Silva, E. J. N. L., Oliveira, M. C. G., Titato, P. C. G., Vasconcelos, B. C., Vivan, R. R., & Alcalde, M. P. (2024). Does the Mixing Method of AH Plus Jet Affect its Physicochemical and Mechanical Properties?. Journal of Endodontics, 50(9), 1333-1339. https://doi.org/10.1016/j.joen.2024.06.006

Vancouver

Rosa SJ, Duarte MAH, Silva EJNL, Oliveira MCG, Titato PCG, Vasconcelos BC, et al. Does the Mixing Method of AH Plus Jet Affect its Physicochemical and Mechanical Properties?. Journal of Endodontics. 2024;50(9):1333-1339. doi:10.1016/j.joen.2024.06.006

BibTeX
@article{Rosa2024,
  author = {Rosa, Stefani Jovedi and Duarte, Marco Antonio Hungaro and Silva, Emmanuel João Nogueira Leal and Oliveira, Maria Carolina Guiotti de and Titato, Pedro Cesar Gomes and Vasconcelos, Bruno Carvalho de and Vivan, Rodrigo Ricci and Alcalde, Murilo Priori},
  title = {Does the Mixing Method of AH Plus Jet Affect its Physicochemical and Mechanical Properties?},
  journal = {Journal of Endodontics},
  year = {2024},
  volume = {50},
  number = {9},
  pages = {1333--1339},
  doi = {10.1016/j.joen.2024.06.006}
}
Kostenlos starten →