Physicochemical performance and biological response of ready-to-use bioceramic endodontic sealers
Clinical Oral Investigations · 2026
DOI: 10.1007/s00784-026-07126-w ↗Kurz gefasst
Fachartikel in der Zeitschrift Clinical Oral Investigations, 2026. Verfasst von Maria Eduarda Paz Dotto und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Endodontics, School of Dental Medicine, University of Pittsburgh, Pittsburgh, USA. Hauptthemen laut MEDLINE: Root Canal Filling Materials, Ceramics. Die Arbeit nennt 44 Literaturangaben.
Abstract (Originalsprache)
Objective
This study evaluated the physicochemical and biological properties of three ready-to-use bioceramic sealers, BioRoot^® Flow (BRF), ZenSeal™ (ZS) and EndoCeramic™ (EC), in comparison with an epoxy resin–based sealer, AH Plus Jet^® (AHP). Materials and methods Setting time, solubility, pH, radiopacity, and flow were assessed following ISO standards. Biological response was evaluated by cell viability using the XTT assay, and gene expression of osteogenic and inflammatory markers was analyzed by quantitative PCR. Data were analyzed at a 5% significance level.
Results
EC showed the shortest initial setting time, followed by ZS, BRF, and AH ( P 0.05). EC exhibited the lowest flow ( P 0.05). Radiopacity was lowest for BRF, followed by EC, ZS, and AHP, with no difference between EC and ZS ( P > 0.05). AHP showed the lowest solubility, followed by EC, ZS, and BRF ( P < 0.001). All sealers demonstrated an alkaline pH, which decreased over time. ZS showed the highest cell viability, followed by EC, BRF, and AHP ( P < 0.05). BRF showed significant upregulation of IL10 , ALPL , TNF , TGFB1 , and TNFSF11 expression with 24 h of exposure ( P < 0.05), whereas at 48 h, TNFSF11 was significantly upregulated with AHP exposure ( P < 0.05).
Conclusions
AHP demonstrated superior physicochemical properties but unfavorable biological properties. Although bioceramic sealers displayed favorable biological properties, their higher solubility may compromise long-term stability and clinical outcome. Clinical relevance Ready-to-use bioceramic sealers may present favorable cytocompatibility, but their increased solubility highlights the need for cautious interpretation, particularly regarding long-term sealing stability.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Endodontics, School of Dental Medicine, University of Pittsburgh, Pittsburgh, USA.
- Department of Endodontics, Health Sciences Center, Universidade Federal de Santa Catarina, Florianópolis, SC, Brazil.
- Department of Endodontics, School of Dentistry, Universidade Federal de Uberlândia - UFU, Uberlândia, MG, Brazil.
- Department of Oral and Craniofacial Sciences, School of Dental Medicine, University of Pittsburgh, Pittsburgh, PA, USA.
- Department of Endodontics, School of Dental Medicine, University of Pittsburgh, Pittsburgh, USA. leticia.souza@pitt.edu.
Zitieren
APA
Dotto, M. E. P., Ferraz, D. C., Kearney, C., Letra, A., Silva, R. M., da Silveira Teixeira, C., & de Souza, L. C. (2026). Physicochemical performance and biological response of ready-to-use bioceramic endodontic sealers. Clinical Oral Investigations. https://doi.org/10.1007/s00784-026-07126-w
Vancouver
Dotto MEP, Ferraz DC, Kearney C, Letra A, Silva RM, da Silveira Teixeira C, et al. Physicochemical performance and biological response of ready-to-use bioceramic endodontic sealers. Clinical Oral Investigations. 2026. doi:10.1007/s00784-026-07126-w
BibTeX
@article{Dotto2026,
author = {Dotto, Maria Eduarda Paz and Ferraz, Danilo Cassiano and Kearney, Caroline and Letra, Ariadne and Silva, Renato Menezes and da Silveira Teixeira, Cleonice and de Souza, Letícia Chaves},
title = {Physicochemical performance and biological response of ready-to-use bioceramic endodontic sealers},
journal = {Clinical Oral Investigations},
year = {2026},
doi = {10.1007/s00784-026-07126-w}
}
EUVIMED