Piezoelectric Device and Dynamic Navigation System Integration for Bone Window-Guided Surgery
Journal of Endodontics · 2023-12 · 49 (12) · 1698-1705
DOI: 10.1016/j.joen.2023.09.013 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Endodontics, 2023-12. Verfasst von Frederico C Martinho und 2 weiteren Autor:innen. Beteiligte Einrichtung: Clinical Professor, Division of Endodontics, Department of Advanced Oral Sciences and Therapeutics, University of Maryland, School of Dentistry, Balt…. Hauptthemen laut MEDLINE: Surgery, Computer-Assisted, Tooth. Die Arbeit wurde bisher 24-mal zitiert (Crossref) und nennt 40 Literaturangaben.
Abstract (Originalsprache)
INTRODUCTION: This study investigates the feasibility of integrating a piezoelectric device (PIEZO) into a dynamic navigation system (DNS) for bone-window guided surgery. It compares the accuracy and efficiency of PIEZO + DNS to PIEZO + Freehand (FH) procedure for bone-window cutting and root-end resection (RER). METHODS: Forty-eight mandibular molars of 3D-printed surgical jaw models were divided into two groups: PIEZO + DNS (n = 24) and PIEZO + FH (n = 24). Cone-beam computed tomography scans were taken before and after the procedure. The procedure was virtually planned on X-guide software. The bone-window cutting and RER were conducted with a PIEZO under dynamic navigation in the PIEZO + DNS group and using the dental operating microscope in the PIEZO + FH group. The 2D- and 3D-accuracy deviations and angular deflection were measured for the bone window cut. The root length resected and resection angle were calculated. The bone window cut, RER, total operating time, and number of mishaps were recorded. RESULTS: PIEZO + DNS was more accurate than PIEZO + FH for bone-window cutting, showing fewer 2D and 3D deviations and less angular deflection (P .05). CONCLUSIONS: Within the limitations of this in vitro study, the integration of a PIEZO into a DNS is feasible for bone-window guided surgery. The DNS improved the accuracy and efficiency of bone-window cutting.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Clinical Professor, Division of Endodontics, Department of Advanced Oral Sciences and Therapeutics, University of Maryland, School of Dentistry, Baltimore, Maryland. Electronic address: fmartinho@umaryland.edu.
- Clinical Assistant Professor, Division of Endodontics, Department of Advanced Oral Sciences and Therapeutics, University of Maryland, School of Dentistry, Baltimore, Maryland.
- Clinical Professor, Division of Endodontics, Department of Advanced Oral Sciences and Therapeutics, University of Maryland, School of Dentistry, Baltimore, Maryland.
Zitieren
APA
Martinho, F. C., Griffin, I. L., & Tordik, P. A. (2023). Piezoelectric Device and Dynamic Navigation System Integration for Bone Window-Guided Surgery. Journal of Endodontics, 49(12), 1698-1705. https://doi.org/10.1016/j.joen.2023.09.013
Vancouver
Martinho FC, Griffin IL, Tordik PA. Piezoelectric Device and Dynamic Navigation System Integration for Bone Window-Guided Surgery. Journal of Endodontics. 2023;49(12):1698-1705. doi:10.1016/j.joen.2023.09.013
BibTeX
@article{Martinho2023,
author = {Martinho, Frederico C and Griffin, Ina L and Tordik, Patricia A},
title = {Piezoelectric Device and Dynamic Navigation System Integration for Bone Window-Guided Surgery},
journal = {Journal of Endodontics},
year = {2023},
volume = {49},
number = {12},
pages = {1698--1705},
doi = {10.1016/j.joen.2023.09.013}
}
EUVIMED