EUVIMEDEUVIMED entdecken
Crossref

The Effect of a Compression Bandage on Dual Energy X-ray Absorptiometry Body Composition Scores

Yamileth Chacón-Araya, Elizabeth Carpio-Rivera, Andrea Quirós-Quirós, José Moncada-Jiménez

Journal of Clinical Densitometry · 2024

DOI: 10.1016/j.jocd.2023.101461 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Clinical Densitometry, 2024. Verfasst von Yamileth Chacón-Araya und 3 weiteren Autor:innen. Beteiligte Einrichtung: Human Movement Sciences Research Center (CIMOHU), University of Costa Rica, Costa Rica; School of Physical Education and Sports, University of Costa …. Hauptthemen laut MEDLINE: Body Composition, Adipose Tissue. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 29 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Dual-energy X-ray absorptiometry (DXA) measures are affected by the noise produced by external factors such as textile compression found in loose clothing. The study aimed to determine the effect of a compression bandage (CB) on body composition (BC) assessed by DXA. METHODS: Sixty volunteers (age=21.4±4.7yr.) underwent full-body DXA scans on a control (CTRL) condition and after wearing a 30-mmHg CB on the trunk, legs, and arms. ANOVA (2 genders by 2 experimental conditions) determined mean interactions in BC variables tissue body fat% (BF%), region body fat% (RBF%), body tissue (BT), fat mass (FM), lean mass (LM), bone mineral content (BMC), and total mass (TM). Absolute reliability in BC scores was studied by the typical error of the measurement (TEM), the coefficient of variability (CV), and Bland-Altman plots. RESULTS: ANOVA interactions were found on tissue total BF% (p=0.049), RBF% (p=0.048), android lean mass (p=0.004), and android total mass (p=0.019). The CV was small for tissue BF% (2.61±0.93%, CI95%=0.79, 4.43%), RBF% (2.66±1.78%, CI95%=-0.83, 6.15%), BT (4.82±2.19%, CI95%=0.54, 9.10kg), FM (4.17±2.25%, CI95%=-0.24, 8.58kg), LM (3.25±2.44%, CI95%=-1.53, 8.04kg), BMC (4.81±2.96%, CI95%=-0.99, 10.62kg), and TM (2.84±2.80%, CI95%=-2.65, 8.33kg). Bland-Altman plots showed random error for BF%, LM, and BMC. A bias of 0.5% was observed on BF% in males. CONCLUSION: A CB worn during a full-body DXA scan elicited similar BC scores than not wearing it. The variation in scores was

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Body CompositionAdipose TissueMaleHumansFemaleAdolescentYoung AdultAdultAbsorptiometry, PhotonReproducibility of ResultsBone Density

Stichwörter der Autor:innen

GarmentQuality controlReliabilityWhole-body compositionX-ray

Autor:innen und Institutionen

  • Human Movement Sciences Research Center (CIMOHU), University of Costa Rica, Costa Rica; School of Physical Education and Sports, University of Costa Rica, Costa Rica.
  • School of Physical Education and Sports, University of Costa Rica, Costa Rica.
  • Human Movement Sciences Research Center (CIMOHU), University of Costa Rica, Costa Rica; School of Physical Education and Sports, University of Costa Rica, Costa Rica. Electronic address: jose.moncada@ucr.ac.cr.

Zitieren

APA

Chacón-Araya, Y., Carpio-Rivera, E., Quirós-Quirós, A., & Moncada-Jiménez, J. (2024). The Effect of a Compression Bandage on Dual Energy X-ray Absorptiometry Body Composition Scores. Journal of Clinical Densitometry. https://doi.org/10.1016/j.jocd.2023.101461

Vancouver

Chacón-Araya Y, Carpio-Rivera E, Quirós-Quirós A, Moncada-Jiménez J. The Effect of a Compression Bandage on Dual Energy X-ray Absorptiometry Body Composition Scores. Journal of Clinical Densitometry. 2024. doi:10.1016/j.jocd.2023.101461

BibTeX
@article{ChacnAraya2024,
  author = {Chacón-Araya, Yamileth and Carpio-Rivera, Elizabeth and Quirós-Quirós, Andrea and Moncada-Jiménez, José},
  title = {The Effect of a Compression Bandage on Dual Energy X-ray Absorptiometry Body Composition Scores},
  journal = {Journal of Clinical Densitometry},
  year = {2024},
  doi = {10.1016/j.jocd.2023.101461}
}
Kostenlos starten →