EUVIMEDEUVIMED entdecken
ValidierungsstudieVergleichsstudie

DXA‐based estimation of body volume in 4‐compartment models: Validating and modifying the Smith‐Ryan equation

Lee Doernte iD, April Spears, Michael Lane

Clinical Physiology and Functional Imaging · 2025

DOI: 10.1111/cpf.70022 ↗

Kurz gefasst

Validierungsstudie in der Zeitschrift Clinical Physiology and Functional Imaging, 2025. Verfasst von Lee Doernte und 2 weiteren Autor:innen. Beteiligte Einrichtung: West Texas A&M University, College of Nursing and Health Science, Canyon, Texas, USA. Hauptthemen laut MEDLINE: Absorptiometry, Photon, Adiposity, Body Composition, Models, Biological. Die Arbeit nennt 21 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Accurate body composition assessment is crucial for evaluating health and guiding interventions. Four‐compartment (4 C) models, which separately quantify fat mass, lean body mass, bone mineral content and total body water, offer improved accuracy but usually require multiple devices. This study aimed to validate dual‐energy X‐ray absorptiometry (DXA)–derived body volume (BV) equations—specifically those from Wilson and Smith‐Ryan—against air displacement plethysmography (ADP), and to modify the Smith‐Ryan equation for enhanced BV estimates in a 4 C model. Ninety healthy adults (50 females, 40 males; aged 18–66 years; BMI 18–34 kg/m²) were recruited at a single‐centre facility. Participants underwent DXA scanning (GE Lunar DXA) for tissue composition, ADP (Bod Pod) for BV, and bioelectrical impedance spectroscopy for total body water, with all measurements performed by trained technicians. BV was estimated using the original Wilson and Smith‐Ryan equations and a regression‐modified Smith‐Ryan equation, and these estimates were incorporated into the 4 C model to calculate percent body fat (%BF) and fat mass (FM). All DXA‐based BV estimates correlated highly with ADP ( r ≥ 0.99). Although the original equations showed small, statistically significant differences in %BF and FM compared to ADP ( p < 0.05), the modified Smith‐Ryan equation produced BV estimates equivalent to ADP ( p = 0.998). These findings suggest that calibrated DXA‐derived BV equations can reliably substitute for ADP in 4 C models, enhancing the accessibility and cost‐effectiveness of body composition analysis. Future research should validate these findings in more diverse populations.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Absorptiometry, PhotonAdiposityBody CompositionModels, BiologicalHumansAdultMiddle AgedMaleFemaleAgedReproducibility of ResultsYoung AdultAdolescentPredictive Value of TestsPlethysmographyBone DensityBody Water

Stichwörter der Autor:innen

DEXASmith‐Ryan equationair displacement plethysmographybody compositionbody volumedual‐energy X‐ray absorptiometryfour‐compartment modelpercent body fat

Autor:innen und Institutionen

  • West Texas A&M University, College of Nursing and Health Science, Canyon, Texas, USA.
  • Eastern Kentucky University, Richmond, USA.

ORCID-Profile: Lee Doernte

Zitieren

APA

Doernte, L., Spears, A., & Lane, M. (2025). DXA‐based estimation of body volume in 4‐compartment models: Validating and modifying the Smith‐Ryan equation. Clinical Physiology and Functional Imaging. https://doi.org/10.1111/cpf.70022

Vancouver

Doernte L, Spears A, Lane M. DXA‐based estimation of body volume in 4‐compartment models: Validating and modifying the Smith‐Ryan equation. Clinical Physiology and Functional Imaging. 2025. doi:10.1111/cpf.70022

BibTeX
@article{Doernte2025,
  author = {Doernte, Lee and Spears, April and Lane, Michael},
  title = {DXA‐based estimation of body volume in 4‐compartment models: Validating and modifying the Smith‐Ryan equation},
  journal = {Clinical Physiology and Functional Imaging},
  year = {2025},
  doi = {10.1111/cpf.70022}
}
Kostenlos starten →