EUVIMEDEUVIMED entdecken
Crossref

A bioreactor for in vitro studies of lymphatic endothelial cells with simultaneous fluid shear stress and membrane strain

C Davis, B Zambrano-Roman, R Sridhar, A Jastram, S Chakraborty, D Zawieja, M R Moreno

Journal of the Mechanical Behavior of Biomedical Materials · 2025-04 · 164 · 106909

DOI: 10.1016/j.jmbbm.2025.106909 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of the Mechanical Behavior of Biomedical Materials, 2025-04. Verfasst von C Davis und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Biomedical Engineering, Texas A&M University, College Station, TX 77843, USA. Hauptthemen laut MEDLINE: Stress, Mechanical, Endothelial Cells, Bioreactors, Shear Strength. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 32 Literaturangaben. Gefördert von: NHLBI NIH HHS, National Institutes of Health, Cancer Prevention and Research Institute of Texas.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Reproducing the in vivo physiologic conditions and biomechanical environment to stimulate natural growth and behavior of lymphatic endothelial cells (LECs) is critical in studying the lymphatic system and its response to stimuli. In vitro studies that deconstruct the biomechanical environment, e.g. independently incorporate flow-induced shear stress or membrane strain have demonstrated the significance of mechanotransduction in LECs (and vascular endothelial cells). Such studies have facilitated the investigation of intracellular signaling pathways stimulated by a particular mechanical cue but do not accurately reproduce natural physiologic behavior of in vivo LECs given the absence of other natural mechanical cues. In this study, we present a novel experimental device designed to reconstruct the in vivo biomechanical environment, i.e. a device that enables the simultaneous application of flow-induced shear stress and cyclic stretching of LECs in vitro. The device is uniquely capable of simulating physiologically-relevant conditions for lymphatic endothelial cells, such as low-flow, high-strain scenarios. Using this device, we observed that, like vascular ECs, LECs aligned in the direction of fluid shear stress when steady flow was applied. In our case the behavior was observed under conditions closer to the physiological mean flow in the lymphatic vessels than vascular levels of shear stress. When concurrent cyclic stretching was applied, the alignment in the direction of flow and perpendicular to the uniaxial stretch was detected in a substantially shortened timeframe. Additionally, the distribution of alignment angles was more closely clustered around 90° under the flow/stretch scenario after 6 h than the 24 h flow only scenario, perhaps indicating a greater sensitivity to cyclic stretching than to fluid shear stress in the morphological alignment response of LECs. We also observed alignment of cell nuclei and F-actin filaments in Human Dermal Lymphatic Endothelial Cells (HDLECs) after only 6 h of combined flow and stretch. These observations underscore the importance of including both sources of mechanical stress when studying the growth and behavior of LECs.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Stress, MechanicalEndothelial CellsBioreactorsShear StrengthCell MembraneMembranes, ArtificialHumansBiomechanical PhenomenaAnimals

Stichwörter der Autor:innen

BioreactorLymphaticsMembrane strainShear stress

Substanzen

Membranes, Artificial

Autor:innen und Institutionen

  • Department of Biomedical Engineering, Texas A&M University, College Station, TX 77843, USA.
  • Department of Mechanical Engineering, Texas A&M University, College Station, TX 77843, USA.
  • Department of Medical Physiology, Texas A&M Health Science Center, College Station, TX 77843, USA.
  • Department of Mechanical Engineering, Texas A&M University, College Station, TX 77843, USA. Electronic address: michael.moreno@tamu.edu.

Förderung

  • NHLBI NIH HHS
  • National Institutes of Health
  • Cancer Prevention and Research Institute of Texas

Zitieren

APA

Davis, C., Zambrano-Roman, B., Sridhar, R., Jastram, A., Chakraborty, S., Zawieja, D., & Moreno, M. R. (2025). A bioreactor for in vitro studies of lymphatic endothelial cells with simultaneous fluid shear stress and membrane strain. Journal of the Mechanical Behavior of Biomedical Materials, 164, 106909. https://doi.org/10.1016/j.jmbbm.2025.106909

Vancouver

Davis C, Zambrano-Roman B, Sridhar R, Jastram A, Chakraborty S, Zawieja D, et al. A bioreactor for in vitro studies of lymphatic endothelial cells with simultaneous fluid shear stress and membrane strain. Journal of the Mechanical Behavior of Biomedical Materials. 2025;164:106909. doi:10.1016/j.jmbbm.2025.106909

BibTeX
@article{Davis2025,
  author = {Davis, C and Zambrano-Roman, B and Sridhar, R and Jastram, A and Chakraborty, S and Zawieja, D and Moreno, M R},
  title = {A bioreactor for in vitro studies of lymphatic endothelial cells with simultaneous fluid shear stress and membrane strain},
  journal = {Journal of the Mechanical Behavior of Biomedical Materials},
  year = {2025},
  volume = {164},
  pages = {106909},
  doi = {10.1016/j.jmbbm.2025.106909}
}
Kostenlos starten →