EUVIMEDEUVIMED entdecken
Crossref

Differential composition and yield of leukocytes isolated from various blood component leukoreduction filters

Katrijn R Six, Sarah Vertongen, Sabrina Seghers, Dominique De Bleser, Veerle Compernolle, Hendrik B Feys

Journal of Immunological Methods · 2024

DOI: 10.1016/j.jim.2024.113733 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Immunological Methods, 2024. Verfasst von Katrijn R Six und 5 weiteren Autor:innen. Beteiligte Einrichtung: Transfusion Research Center, Belgian Red Cross Flanders, Ghent, Belgium. Electronic address: katrijn.six@rodekruis.be. Hauptthemen laut MEDLINE: Leukocyte Reduction Procedures, Leukocytes. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 28 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

In Flanders, an estimated 300,000 leukoreduction filters are discarded as biological waste in the blood establishment each year. These filters are a possible source of fresh donor leukocytes for downstream purposes including research. We investigated leukocyte isolation from two types of filters either used for the preparation of platelet concentrates (PC-LRF) or erythrocyte concentrates (EC-LRF). Outcome parameters were leukocyte yield, differential count, turnaround time and effect of storage conditions. Leukocytes were harvested by reverse flow of a buffer solution. Control was the gold standard density gradient centrifugation of buffy coats. Total leukocyte number isolated from PC-LRF (1049 (± 40) x 106) was almost double that of control (632 (± 66) x 106) but the differential count was comparable. Total leukocyte number isolated from EC-LRF (78 (± 9) x 106) was significantly lower than control, but the sample was specifically enriched in granulocytes (81 ± 4%) compared to control (30 ± 1%). Isolation of leukocytes from either PC- or EC-LRF takes 20 min compared to 240 min for control density gradient centrifugation. Leukocyte viability is optimal when harvested on day 1 post donation (95 ± 0.9%) compared to day 3 (76.4 ± 2.4%). In conclusion, our study demonstrates that leukoreduction filters from specific blood component processing are easy to use and present a valuable source for viable leukocytes of all types.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Leukocyte Reduction ProceduresLeukocytesHumansLeukocyte CountErythrocytesCentrifugation, Density GradientCell SurvivalBlood PlateletsFiltrationTime Factors

Stichwörter der Autor:innen

Blood processingLeukocyte filterLeukocytes

Autor:innen und Institutionen

  • Transfusion Research Center, Belgian Red Cross Flanders, Ghent, Belgium. Electronic address: katrijn.six@rodekruis.be.
  • Transfusion Research Center, Belgian Red Cross Flanders, Ghent, Belgium.
  • Transfusion Innovation Center, Belgian Red Cross Flanders, Ghent, Belgium.
  • Transfusion Research Center, Belgian Red Cross Flanders, Ghent, Belgium; Transfusion Innovation Center, Belgian Red Cross Flanders, Ghent, Belgium; Faculty of Medicine and Health Sciences, Ghent University, Ghent, Belgi…
  • Transfusion Research Center, Belgian Red Cross Flanders, Ghent, Belgium; Faculty of Medicine and Health Sciences, Ghent University, Ghent, Belgium.

Zitieren

APA

Six, K. R., Vertongen, S., Seghers, S., De Bleser, D., Compernolle, V., & Feys, H. B. (2024). Differential composition and yield of leukocytes isolated from various blood component leukoreduction filters. Journal of Immunological Methods. https://doi.org/10.1016/j.jim.2024.113733

Vancouver

Six KR, Vertongen S, Seghers S, De Bleser D, Compernolle V, Feys HB. Differential composition and yield of leukocytes isolated from various blood component leukoreduction filters. Journal of Immunological Methods. 2024. doi:10.1016/j.jim.2024.113733

BibTeX
@article{Six2024,
  author = {Six, Katrijn R and Vertongen, Sarah and Seghers, Sabrina and De Bleser, Dominique and Compernolle, Veerle and Feys, Hendrik B},
  title = {Differential composition and yield of leukocytes isolated from various blood component leukoreduction filters},
  journal = {Journal of Immunological Methods},
  year = {2024},
  doi = {10.1016/j.jim.2024.113733}
}
Kostenlos starten →