EUVIMEDEUVIMED entdecken
ValidierungsstudieOpen Access · CC BY-NC 4.0

Telemedicine-based measurement of finger joint range of motion in patients: A reliability and concurrent validity study

Sasha Létourneau, Omar Salem Taboun, Caroline Esmonde-White, Rohin Ahluwalia, Joy MacDermid, Caitlin Symonette, Douglas Ross, Ruby Grewal

Journal of Hand Therapy · 2026-04 · 39 (2) · 377-386

DOI: 10.1016/j.jht.2025.07.004 ↗

Kurz gefasst

Validierungsstudie in der Zeitschrift Journal of Hand Therapy, 2026-04. Verfasst von Sasha Létourneau und 7 weiteren Autor:innen. Beteiligte Einrichtung: Division of Plastic and Reconstructive Surgery, Western University, London, ON, Canada. Electronic address: sletourneau@qmed.ca. Hauptthemen laut MEDLINE: Telemedicine, Range of Motion, Articular, Arthrometry, Articular, Finger Joint. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 51 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Although the use of telemedicine has persisted in hand surgery and therapy practices beyond the COVID-19 pandemic, there remains a need for simple, validated means of remotely measuring finger joint range of motion for integration in fast-paced virtual clinics. We propose on-screen measurement, a technique previously validated in the elbow, which involves holding a goniometer up to the telemedicine appointment screen. PURPOSE: This study aimed to determine the reliability and concurrent validity of on-screen measurements relative to the gold standard, in-person goniometry. Congruence of management plans established at virtual and in-person appointments was as a secondary aim. STUDY DESIGN: Prospective Reliability and Agreement (Concurrent Validity) Study. METHODS: Patients with Dupuytren's disease assessed virtually and in-person were recruited from one surgeon's practice. Virtual and in-person measurements in maximal passive extension, time between appointments and treatment plans made at each visit were extracted from patients' charts. In-person assessors were blinded to previous telemedicine-based measurements and, after a 2-week washout period, the original assessor and two additional assessors re-measured joints from screenshots captured at telemedicine appointment. Descriptive and statistical analyses were used to evaluate inter-rater and intra-rater reliability as well as concurrent validity. RESULTS: Fifty-four eligible patients (191 joints; 102 digits) attended telemedicine and in-person appointments at a median of 31 days apart. Inter-rater and intra-rater reliability were excellent (intraclass correlation coefficient >0.96). The absolute mean difference between on-screen and in-person measurements was 8˚, with 61.7% of on-screen measurements falling within 10˚ of in-person measurements. Management plans made at the telemedicine appointment were congruent with those carried out in-person in 96.3% of cases. CONCLUSIONS: On-screen measurement is highly reliable with concurrent validity that compares to similar photography-based measurement studies. Our results suggest on-screen measurement may be a useful tool for initial consultation and triaging of patients with flexion contractures.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

TelemedicineRange of Motion, ArticularArthrometry, ArticularFinger JointDupuytren ContractureHumansFemaleReproducibility of ResultsMaleProspective StudiesMiddle AgedAgedCOVID-19Adult

Stichwörter der Autor:innen

AgreementDupuytren’s diseaseFinger goniometryFinger joint range of motionValidation study

Autor:innen und Institutionen

  • Division of Plastic and Reconstructive Surgery, Western University, London, ON, Canada. Electronic address: sletourneau@qmed.ca.
  • Schulich School of Medicine and Dentistry, Western University, London, ON, Canada.
  • Faculty of Science, Western University, London, ON, Canada.
  • School of Rehabilitation Science, McMaster University, London, ON, Canada; Roth | McFarlane Hand and Upper Limb Centre, St. Joseph's Health Care, London, ON, Canada.
  • Division of Plastic and Reconstructive Surgery, Western University, London, ON, Canada; London Health Sciences Centre and London Children's Hospital, London, ON, Canada.
  • Division of Plastic and Reconstructive Surgery, Western University, London, ON, Canada; Roth | McFarlane Hand and Upper Limb Centre, St. Joseph's Health Care, London, ON, Canada.

Zitieren

APA

Létourneau, S., Taboun, O. S., Esmonde-White, C., Ahluwalia, R., MacDermid, J., Symonette, C., Ross, D., & Grewal, R. (2026). Telemedicine-based measurement of finger joint range of motion in patients: A reliability and concurrent validity study. Journal of Hand Therapy, 39(2), 377-386. https://doi.org/10.1016/j.jht.2025.07.004

Vancouver

Létourneau S, Taboun OS, Esmonde-White C, Ahluwalia R, MacDermid J, Symonette C, et al. Telemedicine-based measurement of finger joint range of motion in patients: A reliability and concurrent validity study. Journal of Hand Therapy. 2026;39(2):377-386. doi:10.1016/j.jht.2025.07.004

BibTeX
@article{Ltourneau2026,
  author = {Létourneau, Sasha and Taboun, Omar Salem and Esmonde-White, Caroline and Ahluwalia, Rohin and MacDermid, Joy and Symonette, Caitlin and Ross, Douglas and Grewal, Ruby},
  title = {Telemedicine-based measurement of finger joint range of motion in patients: A reliability and concurrent validity study},
  journal = {Journal of Hand Therapy},
  year = {2026},
  volume = {39},
  number = {2},
  pages = {377--386},
  doi = {10.1016/j.jht.2025.07.004}
}
Kostenlos starten →