EUVIMEDEUVIMED entdecken
Beobachtungsstudie

Reliability, validity and responsiveness of composite finger flexion in patients with traumatic hand injuries: A clinical measurement study

Zeal Kadakia, Rafael Paolo Lansang, Pam Ball, Ayse Kuspinar, Sandra VanderKaay, Tara Packham

Journal of Hand Therapy · 2024

DOI: 10.1016/j.jht.2023.12.001 ↗

Kurz gefasst

Beobachtungsstudie in der Zeitschrift Journal of Hand Therapy, 2024. Verfasst von Zeal Kadakia und 5 weiteren Autor:innen. Beteiligte Einrichtung: School of Rehabilitation Sciences, McMaster University, Ontario, Canada. Electronic address: kadakiaz@mcmaster.ca. Hauptthemen laut MEDLINE: Range of Motion, Articular, Hand Injuries. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 42 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Composite finger flexion (CFF) is proposed to be a convenient alternative to total active motion (TAM) and total passive motion (TPM). Passive CFF (PCFF) may be useful for early monitoring in post-operative rehabilitation of traumatic hand injuries. PURPOSE: To determine whether active and passive CFF are reliable, valid, and responsive measures of hand motion and of higher utility to the tester. STUDY DESIGN: Cross-sectional observational clinical measurement study. METHODS: Fifty hand injury patients were recruited from a hospital-based out-patient clinic. TAM, TPM, repeated measures of active CFF (ACFF) and PCFF, self-reported stiffness, patient reported wrist/hand evaluation (PRWHE) scores, and grip strength were recorded. Intraclass correlation coefficients (ICCs) and standard error of measurement were calculated for inter-rater and test-retest reliability. Criterion and construct validity were assessed using correlation coefficients. Responsiveness was explored by calculating correlation coefficients of change scores, effect sizes, and standardized response means. Time taken to measure CFF and TAM/TPM was recorded to consider utility. RESULTS: The average age of participants was 47 years and 36% were female. Inter-rater and test-retest reliability estimates for ACFF and PCFF were excellent (ICCs = 0.95-98). Standard error of measurement values ranged from 0.21 to 0.33. The correlation coefficient for criterion validity between ACFF and TAM was -0.69; PCFF and TPM was -0.65; and ACFF and PCFF was 0.83. For construct validity, ACFF and TAM were similarly correlated with PRWHE. Correlations between changes in stiffness with ACFF and PCFF were 0.43 and 0.26, respectively. Effect sizes of ACFF and PCFF were small at 0.1 and 0.2. Time taken to measure CFF was much shorter than TAM/TPM. CONCLUSIONS: The results of this study support the use of active and passive CFF as a reliable, valid, and efficient tool in the clinical setting. Further study is required to verify the responsiveness of CFF.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Range of Motion, ArticularHand InjuriesHumansFemaleMaleMiddle AgedReproducibility of ResultsCross-Sectional StudiesAdultHand StrengthAgedDisability EvaluationFinger Joint

Stichwörter der Autor:innen

Composite finger flexionGoniometryReliabilityValidity

Autor:innen und Institutionen

  • School of Rehabilitation Sciences, McMaster University, Ontario, Canada. Electronic address: kadakiaz@mcmaster.ca.
  • Michael G. Degroote School of Medicine, McMaster University, Ontario, Canada.
  • Regional Rehabilitation Centre, Hamilton Health Sciences, Ontario, Canada.
  • School of Rehabilitation Sciences, McMaster University, Ontario, Canada.

Zitieren

APA

Kadakia, Z., Lansang, R. P., Ball, P., Kuspinar, A., VanderKaay, S., & Packham, T. (2024). Reliability, validity and responsiveness of composite finger flexion in patients with traumatic hand injuries: A clinical measurement study. Journal of Hand Therapy. https://doi.org/10.1016/j.jht.2023.12.001

Vancouver

Kadakia Z, Lansang RP, Ball P, Kuspinar A, VanderKaay S, Packham T. Reliability, validity and responsiveness of composite finger flexion in patients with traumatic hand injuries: A clinical measurement study. Journal of Hand Therapy. 2024. doi:10.1016/j.jht.2023.12.001

BibTeX
@article{Kadakia2024,
  author = {Kadakia, Zeal and Lansang, Rafael Paolo and Ball, Pam and Kuspinar, Ayse and VanderKaay, Sandra and Packham, Tara},
  title = {Reliability, validity and responsiveness of composite finger flexion in patients with traumatic hand injuries: A clinical measurement study},
  journal = {Journal of Hand Therapy},
  year = {2024},
  doi = {10.1016/j.jht.2023.12.001}
}
Kostenlos starten →