EUVIMEDEUVIMED entdecken
BeobachtungsstudieOpen Access · CC BY 4.0

A Standardised Car Seat Transfer Test: Reliability and Concurrent Validity

Tarcisio F de Campos iD, Mitchell Wolden iD, Marie K March iD, Deshitha Hewawasam iD, Brandon Boumelhem, Jessica J Spurr, James M Khoury, Nick Vertzyas iD, Steven G Faux iD, Gregory C Gass iD, Sean F Mungovan iD

Occupational Therapy International · 2025

DOI: 10.1155/oti/7306142 ↗

Kurz gefasst

Beobachtungsstudie in der Zeitschrift Occupational Therapy International, 2025. Verfasst von Tarcisio F de Campos und 10 weiteren Autor:innen. Beteiligte Einrichtung: JW & M Cunningham Orthopaedic Clinical Research Fellow, St Vincent's Private Hospital, Sydney, New South Wales, Australia. Hauptthemen laut MEDLINE: Automobiles. Die Arbeit nennt 30 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: St Vincent's Curran Foundation.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

Transferring effectively into and out of a vehicle seat is required for functional mobility and social participation. Reliable and valid vehicle and simulator car seat transfer tests are limited. The aim of this study was to assess the reliability and concurrent validity of a car seat transfer test for application with a vehicle and a simulator car seat.

Methods

A cross‐sectional study was conducted and reported according to the Guidelines for Reporting Reliability and Agreement Studies (GRRAS), the Strengthening the Reporting of Observational Studies in Epidemiology (STROBE) statements and the National Statement on Ethical Conduct in Human Research 2007. Consecutive healthy adults who expressed interest and met the inclusion criteria were recruited for our study. A standardised vehicle and simulator car seat transfer test was undertaken on two visits, 7 days apart. WOMAC, hip and knee active range of motion assessment, self‐selected gait speed measurement and the five‐repetition sit‐to‐stand test were undertaken on the first visit.

Results

Complete data collection was performed with 42 healthy adults. There was good interrater (ICC = 0.99; 95% CI 0.99, 1.00), intrarater (ICC = 0.79; 95% CI 0.62, 0.89 to ICC = 0.91; 95% CI 0.76, 0.96) and test–retest reliability (ICC = 0.87; 95% CI 0.77, 0.93 to ICC = 0.94; 95% CI 0.89, 0.96) for car seat transfer test times for getting into and out of the vehicle and the simulator car seat. There were strong and significant correlations ( r = 0.84–0.89) between the vehicle and simulator car seat test times; these times correlated significantly with measures of physical function including self‐selected gait speed and five‐repetition sit‐to‐stand test results ( p < 0.001).

Conclusion

A standardised car seat transfer test is reliable and valid for testing car seat transfer ability in a vehicle and a simulator car seat.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

AutomobilesAdultFemaleHumansMaleMiddle AgedYoung AdultCross-Sectional StudiesRange of Motion, ArticularReproducibility of Results

Stichwörter der Autor:innen

activities of daily livingautomobilescar transferreliabilityvalidity

Autor:innen und Institutionen

  • JW & M Cunningham Orthopaedic Clinical Research Fellow, St Vincent's Private Hospital, Sydney, New South Wales, Australia.
  • St Vincent's Private Allied Health Services, St Vincent's Private Hospital, Sydney, New South Wales, Australia.
  • Physical Therapy Program, University of Jamestown, Fargo, North Dakota, USA.
  • The Clinical Research Institute, Sydney, New South Wales, Australia.
  • Faculty of Medicine and Health, University of Sydney, Camperdown, New South Wales, Australia.
  • Department of Orthopaedic Surgery, St Vincent's Private Hospital, Sydney, New South Wales, Australia.

ORCID-Profile: Tarcisio F de Campos, Mitchell Wolden, Marie K March, Deshitha Hewawasam, Nick Vertzyas, Steven G Faux, Gregory C Gass, Sean F Mungovan

Förderung

  • St Vincent's Curran Foundation

Zitieren

APA

de Campos, T. F., Wolden, M., March, M. K., Hewawasam, D., Boumelhem, B., Spurr, J. J., Khoury, J. M., Vertzyas, N., Faux, S. G., Gass, G. C., & Mungovan, S. F. (2025). A Standardised Car Seat Transfer Test: Reliability and Concurrent Validity. Occupational Therapy International. https://doi.org/10.1155/oti/7306142

Vancouver

de Campos TF, Wolden M, March MK, Hewawasam D, Boumelhem B, Spurr JJ, et al. A Standardised Car Seat Transfer Test: Reliability and Concurrent Validity. Occupational Therapy International. 2025. doi:10.1155/oti/7306142

BibTeX
@article{deCampos2025,
  author = {de Campos, Tarcisio F and Wolden, Mitchell and March, Marie K and Hewawasam, Deshitha and Boumelhem, Brandon and Spurr, Jessica J and Khoury, James M and Vertzyas, Nick and Faux, Steven G and Gass, Gregory C and Mungovan, Sean F},
  title = {A Standardised Car Seat Transfer Test: Reliability and Concurrent Validity},
  journal = {Occupational Therapy International},
  year = {2025},
  doi = {10.1155/oti/7306142}
}
Kostenlos starten →