Airborne fungal and particle mitigation in HVAC systems: an evaluation trial in a coastal healthcare facility
Journal of Hospital Infection · 2026-11 · 177 · 218-227
DOI: 10.1016/j.jhin.2026.09.007 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Hospital Infection, 2026-11. Verfasst von Dino Pisaniello und 3 weiteren Autor:innen. Beteiligte Einrichtung: School of Public Health, Adelaide University, Adelaide, South Australia, Australia. Electronic address: dino.pisaniello@adelaide.edu.au. Hauptthemen laut MEDLINE: Air Microbiology, Fungi, Air Conditioning. Die Arbeit nennt 28 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
INTRODUCTION: Exposure to airborne fungi can lead to serious health outcomes for vulnerable hospital patients, especially where the facility is situated in a humid environment. Moist conditions can lead to fungal colonisation within air conditioning systems (HVAC), particularly centralised ducted systems such as those typical within healthcare applications. Advanced air cleaning systems can potentially provide both filtration of airborne fungi and decontamination. The primary aim of this study was to compare the performance of a traditional mechanical filter with an advanced air cleaner with multiple modes of bioaerosol mitigation (AMAC). METHODS: An intervention trial was conducted in a healthcare facility in a semi-tropical location where there is also the potential for seawater aerosol impaction adding to moisture load. Airborne fungi and size-resolved airborne particles were monitored at various points in the air handling unit (AHU) and supply ducts, before and after the installation of the new air cleaner (first intervention). Filter cartridge air sampling coupled with light microscopy were used to determine airborne fungal concentrations and broad taxonomic profiles. FINDINGS: Common fungal types found were Cladosporium, Aureobasidium, Aspergillus- and Penicillium-like structures, often associated with fungal growth in HVAC systems. Post AMAC installation, filtration efficiency rose from 86.7 to 99.9%. However, total airborne fungal structure concentrations (TAFSC) increased as air left the AHU (rising from 1 to 22 fs/m3) and further at the Nurse Unit Manager's office supply air register (NUMSAR, 387 fs/m3). This was consistent with inspection and surface testing of duct contamination downstream of the AHU filter. Following subsequent duct replacement and cleaning of contaminated surfaces (second intervention), TAFSC at the NUMSAR were lowered further to 171 fs/m3. Concentrations of Aspergillus/Penicillium spp. reduced significantly from 151 to
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- School of Public Health, Adelaide University, Adelaide, South Australia, Australia. Electronic address: dino.pisaniello@adelaide.edu.au.
- LITMAS, Victoria Point, Queensland, Australia.
- School of Public Health, Adelaide University, Adelaide, South Australia, Australia.
- Stantec, Merivale St, Brisbane, Queensland, Australia.
Zitieren
APA
Pisaniello, D., Bird, C., Nguyen, L., & Chambers, P. (2026). Airborne fungal and particle mitigation in HVAC systems: an evaluation trial in a coastal healthcare facility. Journal of Hospital Infection, 177, 218-227. https://doi.org/10.1016/j.jhin.2026.09.007
Vancouver
Pisaniello D, Bird C, Nguyen L, Chambers P. Airborne fungal and particle mitigation in HVAC systems: an evaluation trial in a coastal healthcare facility. Journal of Hospital Infection. 2026;177:218-227. doi:10.1016/j.jhin.2026.09.007
BibTeX
@article{Pisaniello2026,
author = {Pisaniello, Dino and Bird, Claire and Nguyen, Linh and Chambers, Patrick},
title = {Airborne fungal and particle mitigation in HVAC systems: an evaluation trial in a coastal healthcare facility},
journal = {Journal of Hospital Infection},
year = {2026},
volume = {177},
pages = {218--227},
doi = {10.1016/j.jhin.2026.09.007}
}
EUVIMED