Impact of indoor ventilation on TB transmission risk: implications of climate change
The International Journal of Tuberculosis and Lung Disease · 2025
DOI: 10.5588/ijtld.25.0129 ↗Kurz gefasst
Fachartikel in der Zeitschrift The International Journal of Tuberculosis and Lung Disease, 2025. Verfasst von B Sack und 16 weiteren Autor:innen. Beteiligte Einrichtung: University of Virginia School of Medicine, Charlottesville, VA, USA. Hauptthemen laut MEDLINE: Ventilation, Air Pollution, Indoor, Air Microbiology, Air Conditioning. Die Arbeit wurde bisher 2-mal zitiert (Crossref). Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NIAID NIH HHS.
Abstract (Originalsprache)
BACKGROUND
Due to rising temperatures, individuals are predicted to spend more time in under-ventilated indoor spaces, increasing TB transmission risk. We studied the impact of indoor ventilation on TB transmission risk in homes of persons with TB and in health care facilities in Puducherry, India.
METHODS
We measured ventilation in air changes per hour (ACH) under different ventilation conditions using a carbon dioxide decay method. We estimated transmission risk using the Wells–Riley equation.
RESULTS
Forty-five measurements were taken in 13 homes and 7 health care spaces. In the closed condition (doors and windows closed, fans off), ACH was low (mean 2.23, standard deviation [SD] 2.27) and TB transmission risk was high at 62% (SD 31%). When air conditioning (AC) was on, ACH reduced to 0.75 (SD 0.51), and TB transmission was highest at 76% (SD 13%). Natural ventilation significantly improved ACH (mean 9.46, SD 3.90; P < 0.001) and TB transmission risk to mean 20% (SD 14%; P < 0.001) compared with the closed condition.
CONCLUSION
TB transmission risk in homes and health care spaces is high, especially with AC on. Adapting to rising temperatures using novel methods of ventilation, cooling, and air purification is critical to TB infection control in the era of climate change.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- University of Virginia School of Medicine, Charlottesville, VA, USA.
- Section of Infectious Diseases, Boston University Chobanian and Avedisian School of Medicine, Boston, MA, USA.
- Jawaharlal Institute of Postgraduate Medical Education and Research, Puducherry, India.
- Boston Medical Center, Boston, MA, USA.
- Section of Infectious Diseases, Boston University Chobanian and Avedisian School of Medicine, Boston, MA, USA;, Boston Medical Center, Boston, MA, USA.
- Johns Hopkins University, Baltimore, MD, USA.
Förderung
- NIAID NIH HHS
Zitieren
APA
Sack, B., Shah, P., Abdul Basith, K. M., Dauphinais, M. R., Jain, K., Martins, M. F., Wallace, S., Lakshminarayanan, S., Cintron, C., Subramanian, S., Sahay, A., Koura, K. G., Pischel, L., Brooks, R., Shenoi, S., Chinnakali, P., & Sinha, P. (2025). Impact of indoor ventilation on TB transmission risk: implications of climate change. The International Journal of Tuberculosis and Lung Disease. https://doi.org/10.5588/ijtld.25.0129
Vancouver
Sack B, Shah P, Abdul Basith KM, Dauphinais MR, Jain K, Martins MF, et al. Impact of indoor ventilation on TB transmission risk: implications of climate change. The International Journal of Tuberculosis and Lung Disease. 2025. doi:10.5588/ijtld.25.0129
BibTeX
@article{Sack2025,
author = {Sack, B and Shah, P and Abdul Basith, K M and Dauphinais, M R and Jain, K and Martins, M F and Wallace, S and Lakshminarayanan, S and Cintron, C and Subramanian, S and Sahay, A and Koura, K G and Pischel, L and Brooks, R and Shenoi, S and Chinnakali, P and Sinha, P},
title = {Impact of indoor ventilation on TB transmission risk: implications of climate change},
journal = {The International Journal of Tuberculosis and Lung Disease},
year = {2025},
doi = {10.5588/ijtld.25.0129}
}