EUVIMEDEUVIMED entdecken
Crossref

Use of ANCHOR viruses to validate radiative, physical and chemical decontamination systems in operational conditions

F Gallardo, V Poirier, C Quentin-Froignant, T Figueroa, R Volmer, A Proust, C Menard, M Rosa-Calatrava, M Mousnier, O Authier, D Lainisalo, P Lainisalo und 3 weitere

Journal of Hospital Infection · 2026-12 · 178 · 116-124

DOI: 10.1016/j.jhin.2026.01.031 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Hospital Infection, 2026-12. Verfasst von F Gallardo und 14 weiteren Autor:innen. Beteiligte Einrichtung: NeoVirTech SAS, Toulouse, France. Electronic address: fgallardo@neovirtech.com. Die Arbeit nennt 20 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

OBJECTIVES: Effective disinfection is essential in settings such as high-containment laboratories, healthcare environments and public spaces, particularly for controlling the spread of pathogenic viruses. Current methods for evaluating disinfection efficacy are time-consuming, often lacking adaptability to real-world conditions. METHODS: This study used ANCHOR-tagged autofluorescent viruses to enable the detection of infectious particles by high-throughput microscopy. These models were used to mimic viral contamination and evaluate disinfection procedures, such as ultraviolet-C (UV-C) light-emitting diode systems, self-decontaminating surfaces, or chemical disinfection of sensitive areas such as biosafety level 4 (BSL-4) showers and pressurized suits. RESULTS: Replicative ANCHOR-tagged viruses demonstrated high environmental persistence [particularly human adenovirus type 5 (hAdV5) and vaccinia virus (VACV)], and retained infectivity profiles suitable for disinfection studies. UV-C irradiation tests showed up to 4 log10 (99.99%) reduction of hAdV5 infectivity on plastic and fabric surfaces after optimization of an ultraviolet disinfection box. Self-decontaminating surfaces achieved >4log10 inactivation of VACV. Following this initial testing, the surface achieved >90% inactivation of respiratory enveloped RNA viruses (e.g. severe acute respiratory syndrome coronavirus 2, H1N1, H5N8) within 30-60 s. BSL-4 operational tests confirmed that current disinfection procedures for suits and decontamination showers are effective (>5-6log10 reduction), although the porous nature of some materials, such as boots, may require additional contact time. CONCLUSIONS: Viral models based on ANCHOR provide a rapid (16 h readout), low-risk and miniaturized tool for evaluating disinfection methods. This technology is a significant asset for early development, quality control and validation of disinfection systems under operational conditions. Although it cannot replace normative testing yet, this method enables the accelerated and cost-effective development of new disinfection systems.

Schlagwörter

Stichwörter der Autor:innen

ANCHOR virusesAutofluorescent virus modelsBSL-4 laboratory safetyDisinfection efficiencyPoxvirusUV-C irradiationViral persistence

Autor:innen und Institutionen

  • NeoVirTech SAS, Toulouse, France. Electronic address: fgallardo@neovirtech.com.
  • NeoVirTech SAS, Toulouse, France.
  • École nationale vétérinaire de Toulouse, Université de Toulouse, ENVT, INRAE, IHAP, UMR 1225, Toulouse, France.
  • VirexpR SAS, Reyrieux, France.
  • International Research Laboratory RespiVir France-Canada, Centre de Recherche en Infectiologie, Faculté de Médecine RTH Laennec, Université Claude Bernard Lyon 1, INSERM, CNRS, ENS de Lyon, Lyon, France; Virnext, Facult…
  • Clinit technologies SAS, Toulouse, France.

Zitieren

APA

Gallardo, F., Poirier, V., Quentin-Froignant, C., Figueroa, T., Volmer, R., Proust, A., Menard, C., Rosa-Calatrava, M., Mousnier, M., Authier, O., Lainisalo, D., Lainisalo, P., Ingelius, T., Grandadam, M., & Marcheteau, E. (2026). Use of ANCHOR viruses to validate radiative, physical and chemical decontamination systems in operational conditions. Journal of Hospital Infection, 178, 116-124. https://doi.org/10.1016/j.jhin.2026.01.031

Vancouver

Gallardo F, Poirier V, Quentin-Froignant C, Figueroa T, Volmer R, Proust A, et al. Use of ANCHOR viruses to validate radiative, physical and chemical decontamination systems in operational conditions. Journal of Hospital Infection. 2026;178:116-124. doi:10.1016/j.jhin.2026.01.031

BibTeX
@article{Gallardo2026,
  author = {Gallardo, F and Poirier, V and Quentin-Froignant, C and Figueroa, T and Volmer, R and Proust, A and Menard, C and Rosa-Calatrava, M and Mousnier, M and Authier, O and Lainisalo, D and Lainisalo, P and Ingelius, T and Grandadam, M and Marcheteau, E},
  title = {Use of ANCHOR viruses to validate radiative, physical and chemical decontamination systems in operational conditions},
  journal = {Journal of Hospital Infection},
  year = {2026},
  volume = {178},
  pages = {116--124},
  doi = {10.1016/j.jhin.2026.01.031}
}
Kostenlos starten →