Optimal operating positions of two air purifiers for improving indoor air quality in hospital wards
Journal of Hospital Infection · 2025
DOI: 10.1016/j.jhin.2025.02.006 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Hospital Infection, 2025. Verfasst von I H An und 4 weiteren Autor:innen. Beteiligte Einrichtung: School of Mechanical Engineering, Hanyang University, Seoul, Republic of Korea. Hauptthemen laut MEDLINE: Air Pollution, Indoor, Ventilation, Air Filters. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 34 Literaturangaben. Gefördert von: National Research Foundation of Korea.
Abstract (Originalsprache)
BACKGROUND: Maintaining high indoor air quality (IAQ) in hospital wards is crucial, particularly in settings lacking proper ventilation. This study investigates the effectiveness of air purifiers in enhancing IAQ under varying conditions, including ventilation systems and curtains. AIM: This study aims to evaluate the optimal operating positions of two air purifiers to enhance IAQ in hospital wards under varying ventilation and curtain use conditions. METHODS: This study employed a combination of experiments and computational fluid dynamics (CFD) simulations across 20 scenarios, analysing the impact of air purifier placement on the age of air, a key IAQ metric. FINDINGS: This study found that the positioning of air purifiers greatly influenced IAQ, with reductions in the age of air ranging from 19% to 44% depending on the configuration. The most effective placement involved active ventilation systems and unfolded curtains, leading to a significant decrease in the volume-averaged age of air. CONCLUSION: This study concludes that optimal placement of air purifiers in hospital wards can significantly improve IAQ, with reductions in the age of air by up to 44%. Specifically, when ventilation systems were active and curtains were unfolded, the age of air was reduced to as low as 318 s, representing a 27-44% improvement over less-effective configurations. These findings emphasize the critical role of strategic air purifier placement in reducing airborne infection risks and enhancing patient safety in healthcare environments.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- School of Mechanical Engineering, Hanyang University, Seoul, Republic of Korea.
- Department of Manufacturing Systems and Design Engineering, Seoul National University of Science and Technology, Seoul, Republic of Korea.
- School of Mechanical Engineering, Hanyang University, Seoul, Republic of Korea. Electronic address: ysjnuri@hanyang.ac.kr.
Förderung
- National Research Foundation of Korea
Zitieren
APA
An, I. H., Kwak, D. B., Lee, J., Park, S. H., & Yook, S. J. (2025). Optimal operating positions of two air purifiers for improving indoor air quality in hospital wards. Journal of Hospital Infection. https://doi.org/10.1016/j.jhin.2025.02.006
Vancouver
An IH, Kwak DB, Lee J, Park SH, Yook SJ. Optimal operating positions of two air purifiers for improving indoor air quality in hospital wards. Journal of Hospital Infection. 2025. doi:10.1016/j.jhin.2025.02.006
BibTeX
@article{An2025,
author = {An, I H and Kwak, D B and Lee, J and Park, S H and Yook, S J},
title = {Optimal operating positions of two air purifiers for improving indoor air quality in hospital wards},
journal = {Journal of Hospital Infection},
year = {2025},
doi = {10.1016/j.jhin.2025.02.006}
}