EUVIMEDEUVIMED entdecken
Crossref

Rotational stability and clinical outcomes after implantation of a new monofocal toric intraocular lens with double C-loop design

C Chassain, M K Hallak, M Lesaffre

Journal Français d'Ophtalmologie · 2023

DOI: 10.1016/j.jfo.2022.07.005 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal Français d'Ophtalmologie, 2023. Verfasst von C Chassain und 2 weiteren Autor:innen. Beteiligte Einrichtung: Clinique Beau Soleil, 119, avenue de Lodève, 34070 Montpellier, France. Electronic address: c.chassain@languedoc-mutualite.fr. Hauptthemen laut MEDLINE: Phacoemulsification, Lenses, Intraocular, Astigmatism, Cataract. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 26 Literaturangaben. Gefördert von: Deutscher Fondsverband.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

PURPOSE: To investigate rotational stability and visual outcomes of patients unilaterally or bilaterally implanted with a new monofocal toric intraocular lens (IOL). SETTING: Ophthalmology service, clinique Beausoleil, avenue de Lodève, Montpellier. DESIGN: Single-center retrospective study. METHODS: This study included patients who underwent routine cataract surgery with the PODEYE toric (BVI/PhysIOL SA, Liège, Belgium) IOL using the ZEISS CALLISTO eye®. Biometry and keratometry data, refractive outcomes, rotational stability, and astigmatism correction were recorded. IOL rotation was evaluated using an image analysis technique. Postoperative assessments were performed at 1 week, 1 month, and 4 to 6 months after surgery. RESULTS: Clinical outcomes of 102 patients (136 eyes) were analyzed. Patients had a mean age of 74 years. Of the included eyes, 25% had an axial length greater than 24.5mm. Median postoperative IOL rotation from baseline (surgery) was 2̊. With the exception of one outlier (15̊ rotation), IOL rotation was ≤ 6̊ (1 month) and ≤ 10̊ (4-6 months) in 100% of the eyes. No surgical IOL re-positioning was required. Median postoperative corrected distance visual acuity was -0.08 logMAR, and median postoperative subjective cylinder was between 0.25 and 0.50 D. CONCLUSION: The PODEYE toric IOL showed high rotational stability, allowing for correction of corneal astigmatism during cataract surgery.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

PhacoemulsificationLenses, IntraocularAstigmatismCataractHumansAgedLens Implantation, IntraocularRetrospective StudiesRefraction, Ocular

Stichwörter der Autor:innen

CataractCataracteIntraocular lensLentille intraoculaireMonofocalMonofocalePODEYERotational stabilityStabilité rotationnelleToricTorique

Autor:innen und Institutionen

  • Clinique Beau Soleil, 119, avenue de Lodève, 34070 Montpellier, France. Electronic address: c.chassain@languedoc-mutualite.fr.
  • Universitätsklinikum Heidelberg, Im Neuenheimer Feld 400, 69120 Heidelberg, Germany.
  • Clinique Beau Soleil, 119, avenue de Lodève, 34070 Montpellier, France.

Förderung

  • Deutscher Fondsverband

Zitieren

APA

Chassain, C., Hallak, M. K., & Lesaffre, M. (2023). Rotational stability and clinical outcomes after implantation of a new monofocal toric intraocular lens with double C-loop design. Journal Français d'Ophtalmologie. https://doi.org/10.1016/j.jfo.2022.07.005

Vancouver

Chassain C, Hallak MK, Lesaffre M. Rotational stability and clinical outcomes after implantation of a new monofocal toric intraocular lens with double C-loop design. Journal Français d'Ophtalmologie. 2023. doi:10.1016/j.jfo.2022.07.005

BibTeX
@article{Chassain2023,
  author = {Chassain, C and Hallak, M K and Lesaffre, M},
  title = {Rotational stability and clinical outcomes after implantation of a new monofocal toric intraocular lens with double C-loop design},
  journal = {Journal Français d'Ophtalmologie},
  year = {2023},
  doi = {10.1016/j.jfo.2022.07.005}
}
Kostenlos starten →