EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Use of VeriQ system in transfemoral aortic valve implantation. A novel technique

Mohamed Zeinah, Ahmed Mostafa Omran

Journal of the Egyptian Society of Cardio-Thoracic Surgery · 2016

DOI: 10.1016/j.jescts.2016.04.004 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of the Egyptian Society of Cardio-Thoracic Surgery, 2016. Verfasst von Mohamed Zeinah und 1 weiteren Autor:innen. Die Arbeit nennt 8 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The use of Doppler/Ultrasound is well documented in Cardiac, Vascular and Transplant surgery. It accurately detects the flow of blood through a vessel, allowing for informed decision making regarding cannulation site, graft anastomosis and assessment of graft patency. Trans-catheter Aortic Valve implantation (TAVI) has recently emerged as an effective treatment of elderly or high risk patients with aortic stenosis. The transfemoral TAVI is the most frequently adopted strategy. However, many patients referred for transfemoral TAVI present some degree of peripheral vascular disease and this is partially responsible for an increased rate of vascular complications. We present our experience in 50 patients who were referred for transfemoral TAVI at Oxford heart centre to confirm the point of access for insertion of the femoral sheath and the quality of the femoral artery repair after direct repair. We present our experience with High risk cases with aortic stenosis. They have been accepted for transfemoral TAVI. In order to confirm the point of access for insertion of the femoral sheath and Quality of repair, we used VeriQ system as standard procedure. The use of VeriQ system is safe and reproducible method to assess the Point of access for insertion of femoral sheath and the quality of the femoral artery after direct repair in transfemoral TAVI.

Zitieren

APA

Zeinah, M., & Omran, A. M. (2016). Use of VeriQ system in transfemoral aortic valve implantation. A novel technique. Journal of the Egyptian Society of Cardio-Thoracic Surgery. https://doi.org/10.1016/j.jescts.2016.04.004

Vancouver

Zeinah M, Omran AM. Use of VeriQ system in transfemoral aortic valve implantation. A novel technique. Journal of the Egyptian Society of Cardio-Thoracic Surgery. 2016. doi:10.1016/j.jescts.2016.04.004

BibTeX
@article{Zeinah2016,
  author = {Zeinah, Mohamed and Omran, Ahmed Mostafa},
  title = {Use of VeriQ system in transfemoral aortic valve implantation. A novel technique},
  journal = {Journal of the Egyptian Society of Cardio-Thoracic Surgery},
  year = {2016},
  doi = {10.1016/j.jescts.2016.04.004}
}
Kostenlos starten →