Enhancing low-level tritium detection in environmental waters: assessing the Hidex ULLA liquid scintillation counter

Lorenzo Copia, Leonard I Wassenaar, Risto Juvonen, Timo Oikari

Journal of Environmental Radioactivity · 2024-12 · 280 · 107545

DOI: 10.1016/j.jenvrad.2024.107545 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Environmental Radioactivity, 2024-12. Verfasst von Lorenzo Copia und 3 weiteren Autor:innen. Beteiligte Einrichtung: International Atomic Energy Agency, Vienna International Centre, A-1400 Vienna, Austria. Electronic address: l.copia@iaea.org. Hauptthemen laut MEDLINE: Tritium, Scintillation Counting, Water Pollutants, Radioactive, Radiation Monitoring. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 25 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Tritium (³H) is a vital tracer in isotope hydrology and environmental studies, necessitating accurate and precise low-level detection methods. This study evaluated the performance of the new Hidex ULLA Liquid Scintillation Counter for ultra-low-level tritium assays in environmental water samples. The optimization of instrumental parameters enabled accurate and reproducible 3H measurements. Test samples (10-132 TU) were analyzed in triplicate, including 3H-free water and NIST traceable standards. The results demonstrated excellent accuracy and reproducibility, as evidenced by Zeta scores and linearity across these tritium concentrations. The system's stability over extended measurement time periods ensured reliable performance for routine ultra-low level 3H analysis. The optimization of key parameters such as coincidence time and region of interest (ROI) achieved the highest figure of merit (FoM) by using a 25 ns coincidence time and the DigPb open mode for optimal spectral fittings. Detection limits (DL) based on ISO11929 recommendations were significantly improved but highlighted the need for sample enrichment for most low-level environmental applications, with LSC counting times preferably exceeding 1000 min. Overall, the Hidex ULLA Liquid Scintillation Counter proved to be a robust and reliable instrument suitable for ultra-low-level tritium detection in environmental water samples.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

TritiumScintillation CountingWater Pollutants, RadioactiveRadiation MonitoringReproducibility of Results

Stichwörter der Autor:innen

3-HDatingGroundwaterLSCLiquid scintillation countingTritium

Substanzen

TritiumWater Pollutants, Radioactive

Autor:innen und Institutionen

  • International Atomic Energy Agency, Vienna International Centre, A-1400 Vienna, Austria. Electronic address: l.copia@iaea.org.
  • International Atomic Energy Agency, Vienna International Centre, A-1400 Vienna, Austria.
  • Hidex Oy, Lemminkäisenkatu 62, FIN-20520, Turku, Finland.

Zitieren

APA

Copia, L., Wassenaar, L. I., Juvonen, R., & Oikari, T. (2024). Enhancing low-level tritium detection in environmental waters: assessing the Hidex ULLA liquid scintillation counter. Journal of Environmental Radioactivity, 280, 107545. https://doi.org/10.1016/j.jenvrad.2024.107545

Vancouver

Copia L, Wassenaar LI, Juvonen R, Oikari T. Enhancing low-level tritium detection in environmental waters: assessing the Hidex ULLA liquid scintillation counter. Journal of Environmental Radioactivity. 2024;280:107545. doi:10.1016/j.jenvrad.2024.107545

BibTeX
@article{Copia2024,
  author = {Copia, Lorenzo and Wassenaar, Leonard I and Juvonen, Risto and Oikari, Timo},
  title = {Enhancing low-level tritium detection in environmental waters: assessing the Hidex ULLA liquid scintillation counter},
  journal = {Journal of Environmental Radioactivity},
  year = {2024},
  volume = {280},
  pages = {107545},
  doi = {10.1016/j.jenvrad.2024.107545}
}
Kostenlos starten →