An in vitro evaluation of aligner force decay in artificial saliva
Journal of Dental Sciences · 2023-07 · 18 (3) · 1347-1353
DOI: 10.1016/j.jds.2023.04.017 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Dental Sciences, 2023-07. Verfasst von Shou-Min Chen und 3 weiteren Autor:innen. Beteiligte Einrichtung: School of Dentistry, College of Oral Medicine, Chung Shan Medical University, Taichung, Taiwan. Die Arbeit wurde bisher 10-mal zitiert (Crossref) und nennt 26 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: Chung Shan Medical University Hospital.
Abstract (Originalsprache)
Background/purpose: The present study aimed to compare the force decay of invisible aligners for maxillary anterior teeth with 0.1 mm (D1), 0.2 mm (D2), and 0.3 mm (D3) labial movement within a simulated oral environment over 7 days. Materials and methods: The prepared invisible aligners were immersed in saliva (S) and subjected to applied force (F) for 7 days. The aligners were set and placed on the maxillary right central incisor with 0.1 mm (D1), 0.2 mm (D2), and 0.3 mm (D3) labial movement. Thin-film pressure sensors were used to measure the aligner force changes. The data were collected and analyzed by statistical methods.
Results
Significant differences were observed in the initial and first-day force between the D2 and D3 groups under simulated oral environment force (SF) (P < 0.05). There was a significant difference in force decay between Day 1 and Day 7 for all groups (P < 0.05). The SFD1 group showed a significant decrease in force on Day 5 (P < 0.05), while the SFD2 and SFD3 groups showed significant force decay on Day 4 (P < 0.05). The force decay ratio on Day 7 was higher in the SFD3 group than in the SFD1 and SFD2 groups, but no significant difference was observed.
Conclusion
Larger labial movement of the aligners resulted in higher force decay under artificial saliva environments, and the force decay of invisible aligners was increased by immersion time in artificial saliva.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- School of Dentistry, College of Oral Medicine, Chung Shan Medical University, Taichung, Taiwan.
- Orthodontic Department, Chung Shan Medical University Hospital, Taichung, Taiwan.
- Dental Department, Chung Shan Medical University Hospital, Taichung, Taiwan.
Förderung
- Chung Shan Medical University Hospital
Zitieren
APA
Chen, S. M., Ho, C. T., Huang, T. H., & Kao, C. T. (2023). An in vitro evaluation of aligner force decay in artificial saliva. Journal of Dental Sciences, 18(3), 1347-1353. https://doi.org/10.1016/j.jds.2023.04.017
Vancouver
Chen SM, Ho CT, Huang TH, Kao CT. An in vitro evaluation of aligner force decay in artificial saliva. Journal of Dental Sciences. 2023;18(3):1347-1353. doi:10.1016/j.jds.2023.04.017
BibTeX
@article{Chen2023,
author = {Chen, Shou-Min and Ho, Chun-Te and Huang, Tsui-Hsein and Kao, Chia-Tze},
title = {An in vitro evaluation of aligner force decay in artificial saliva},
journal = {Journal of Dental Sciences},
year = {2023},
volume = {18},
number = {3},
pages = {1347--1353},
doi = {10.1016/j.jds.2023.04.017}
}
EUVIMED