EUVIMEDEUVIMED entdecken
Open Access

Eccentricity and greater size of the glenosphere increase impingement-free range of motion in glenoid lateralized reverse shoulder arthroplasty: A computational study

Edoardo Franceschetti, Giovanni Perricone, Antonino De Rosa, Andrea Tanzilli, Pietro Gregori, Giancarlo Giurazza, Biagio Zampogna, Saseendar Shanmugasundaram, Rocco Papalia

Journal of Clinical Orthopaedics and Trauma · 2024-09 · 56 · 102527

DOI: 10.1016/j.jcot.2024.102527 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Clinical Orthopaedics and Trauma, 2024-09. Verfasst von Edoardo Franceschetti und 8 weiteren Autor:innen. Beteiligte Einrichtung: Fondazione Policlinico Universitario Campus Bio-Medico, Via Alvaro del Portillo, 200, 00128, Roma, Italy. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 18 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

Increasing the impingement-free Range Of Movement (ROM) is crucial for improving patient's functional outcome and reducing the rate of scapular notching. The purpose of this study was to compare, in a virtual model of Reverse Shoulder Arthroplasty with glenoid lateralization (L-RSA): 1) the impingement-free range of movement (ROM) between 155° Grammont-style inlay stem and 135° flushlay stem; 2) the effect of glenosphere size and type (centered vs eccentric) on impingement-free range of movement (ROM) using a 135° Neck Shaft Angle (NSA) flushlay stem. Materials and methods: 200 CT-scans of patients undergoing shoulder replacement for Cuff tear Arthropathy were analyzed in the present study. Virtual implantation of L-RSA was performed using the same glenoid implant and two stems, 155° inlay Grammont-style stem and 135° flushlay stem. For 135° stem, three different glenoid size (36 mm, 39 mm and 42 mm) were tried, as well as two glenoid type (centered and eccentric glenoid), while for 155° stem were tried two different glenoid size (36 mm and 42 mm), as well as two glenoid type (centered and eccentric glenoid). For both stems, two different baseplates (25 mm e 29 mm) were used. Finally, impingement-free ROM for each configuration and each stem was then calculated by the software and collected.

Results

Increasing the glenosphere size demonstrated an increase in impingement-free ROM in both 25 mm and 29 mm baseplate groups (p < 0.01). Similarly, using eccentric glenoid type improved impingement-free ROM in the two subgroups (p < 0.01). When comparing inlay and flushlay designs, flushlay shows better total impingement-free ROM as well as better impingement-free ROM in all movements apart from abduction (p < 0.01).

Conclusions

This study demonstrated a correlation between glenoid size and glenoid type and impingement-free ROM using 135° flushlay stems. In particular, using a greater glenoid size and eccentric glenoid type allows for more mobility. When comparing 135° flushlay stem with 155° inlay stem, 135° stem allows greater mobility in all movements except for abduction.

Autor:innen und Institutionen

  • Fondazione Policlinico Universitario Campus Bio-Medico, Via Alvaro del Portillo, 200, 00128, Roma, Italy.
  • Research Unit of Orthopaedic and Trauma Surgery, Department of Medicine and Surgery, Università Campus Bio-Medico di Roma, Via Alvaro del Portillo, 21, 00128, Roma, Italy.
  • Sri Lakshmi Narayana Institute of Medical Sciences, Puducherry, India.

Zitieren

APA

Franceschetti, E., Perricone, G., De Rosa, A., Tanzilli, A., Gregori, P., Giurazza, G., Zampogna, B., Shanmugasundaram, S., & Papalia, R. (2024). Eccentricity and greater size of the glenosphere increase impingement-free range of motion in glenoid lateralized reverse shoulder arthroplasty: A computational study. Journal of Clinical Orthopaedics and Trauma, 56, 102527. https://doi.org/10.1016/j.jcot.2024.102527

Vancouver

Franceschetti E, Perricone G, De Rosa A, Tanzilli A, Gregori P, Giurazza G, et al. Eccentricity and greater size of the glenosphere increase impingement-free range of motion in glenoid lateralized reverse shoulder arthroplasty: A computational study. Journal of Clinical Orthopaedics and Trauma. 2024;56:102527. doi:10.1016/j.jcot.2024.102527

BibTeX
@article{Franceschetti2024,
  author = {Franceschetti, Edoardo and Perricone, Giovanni and De Rosa, Antonino and Tanzilli, Andrea and Gregori, Pietro and Giurazza, Giancarlo and Zampogna, Biagio and Shanmugasundaram, Saseendar and Papalia, Rocco},
  title = {Eccentricity and greater size of the glenosphere increase impingement-free range of motion in glenoid lateralized reverse shoulder arthroplasty: A computational study},
  journal = {Journal of Clinical Orthopaedics and Trauma},
  year = {2024},
  volume = {56},
  pages = {102527},
  doi = {10.1016/j.jcot.2024.102527}
}
Kostenlos starten →