EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 4.0

Use of custom glenoid components for reverse total shoulder arthroplasty

Punyawat Apiwatanakul, Prashant Meshram, Andrew B Harris, Joel Bervell, Piotr Łukasiewicz, Ridge Maxson, Matthew J Best, Edward G McFarland

Clinics in Shoulder and Elbow · 01.12.2023 · 26 (4) · 343-350

DOI: 10.5397/cise.2023.00563 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Clinics in Shoulder and Elbow, erschienen am 01.12.2023. Verfasst von Punyawat Apiwatanakul und 7 weiteren Autor:innen. Beteiligte Einrichtung: Division of Shoulder and Elbow Surgery, Department of Orthopaedic Surgery, The Johns Hopkins University, Baltimore, MD, USA. Die Arbeit wurde bisher 14-mal zitiert (Crossref) und nennt 29 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background:Our purpose was to evaluate a custom reverse total shoulder arthroplasty glenoid baseplate for severe glenoid deficiency, emphasizing the challenges with this approach, including short-term clinical and radiographic outcomes and complications.

Methods

This was a single-institution, retrospective series of 29 patients between January 2017 and December 2022 for whom a custom glenoid component was created for extensive glenoid bone loss. Patients were evaluated preoperatively and at intervals for up to 5 years. All received preoperative physical examinations, plain radiographs, and computed tomography (CT). Intra- and postoperative complications are reported.

Results

Of 29 patients, delays resulted in only undergoing surgery, and in three of those, the implant did not match the glenoid. For those three, the time from CT scan to implantation averaged 7.6 months (range, 6.1–10.7 months), compared with 5.5 months (range, 2–8.6 months) for those whose implants fit. In patients with at least 2-year follow-up (n=9), no failures occurred. Significant improvements were observed in all patient-reported outcome measures in those nine patients (American Shoulder and Elbow Score, P

Schlagwörter

Stichwörter der Autor:innen

Glenoid bone lossReverseShoulderTreatment outcomesArthroplasty

Autor:innen und Institutionen

  • Division of Shoulder and Elbow Surgery, Department of Orthopaedic Surgery, The Johns Hopkins University, Baltimore, MD, USA.

Zitieren

APA

Apiwatanakul, P., Meshram, P., Harris, A. B., Bervell, J., Łukasiewicz, P., Maxson, R., Best, M. J., & McFarland, E. G. (2023). Use of custom glenoid components for reverse total shoulder arthroplasty. Clinics in Shoulder and Elbow, 26(4), 343-350. https://doi.org/10.5397/cise.2023.00563

Vancouver

Apiwatanakul P, Meshram P, Harris AB, Bervell J, Łukasiewicz P, Maxson R, et al. Use of custom glenoid components for reverse total shoulder arthroplasty. Clinics in Shoulder and Elbow. 2023;26(4):343-350. doi:10.5397/cise.2023.00563

BibTeX
@article{Apiwatanakul2023,
  author = {Apiwatanakul, Punyawat and Meshram, Prashant and Harris, Andrew B and Bervell, Joel and Łukasiewicz, Piotr and Maxson, Ridge and Best, Matthew J and McFarland, Edward G},
  title = {Use of custom glenoid components for reverse total shoulder arthroplasty},
  journal = {Clinics in Shoulder and Elbow},
  year = {2023},
  volume = {26},
  number = {4},
  pages = {343--350},
  doi = {10.5397/cise.2023.00563}
}
Kostenlos starten →