EUVIMEDEUVIMED entdecken
Crossref

Enhanced performances of the coupled thermal conductive heating-groundwater circulation well approach

Xinglu Hu, Yue Hu, Chuankun Liu, Weijia Wang, Shengyan Pu, Tong Jiao, Chunmiao Zheng

Journal of Contaminant Hydrology · 2026-05 · 280 · 104928

DOI: 10.1016/j.jconhyd.2026.104928 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Contaminant Hydrology, 2026-05. Verfasst von Xinglu Hu und 6 weiteren Autor:innen. Beteiligte Einrichtung: State Key Laboratory of Geohazard Prevention and Geoenvironment Protection (Chengdu University of Technology), Chengdu 610059, China; College of Envi…. Hauptthemen laut MEDLINE: Groundwater, Water Pollutants, Chemical, Nitrobenzenes, Environmental Restoration and Remediation. Die Arbeit nennt 61 Literaturangaben. Gefördert von: National Key Research and Development Program of China, Natural Science Foundation of Sichuan Province, National Natural Science Foundation of China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Most studies about the groundwater circulation well (GCW) and relevant approaches coupled with other remediation techniques were conducted under ambient temperature conditions. To address this gap, using a series of laboratory-scale sandbox experiments, complemented by numerical simulations, the present study aims to evaluate the remediation performances of this coupled thermal conductive heating (TCH) - GCW system for both the conservative tracer (brilliant blue) and the semi-volatile organic pollutant (nitrobenzene). For the conservative tracer, the remediation processes of the GCW were significantly expedited by heating, but the final remediated area and the remediation efficiency demonstrated similar results for different heating conditions. For example, under the heating temperature of 110 °C, the required remediation time consumption results for observation points had reduced by 2.5%-50% compared with the no-heating condition, but the final remediated area results under heating conditions only increased by less than 6%. For nitrobenzene, higher heating temperatures can lead to better remediation performances, especially in tailing zones. Under the heating conditions, the remediated areas of nitrobenzene increased from 53.95% to 99.74%, and the required remediation time consumption results decreased by 4%-95%. Based on scenario analysis using numerical simulations, the relative contributions of four mechanism processes for removing nitrobenzene using the TCH-GCW approach were quantified and ranked as: convection > > hydrodynamic dispersion > volatilization > adsorption, while the removal of the conservative tracer was attributed to convection. The removed masses and relative contributions of nitrobenzene due to dispersion and volatilization increased as the heating temperature increased.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

GroundwaterWater Pollutants, ChemicalNitrobenzenesEnvironmental Restoration and RemediationHot TemperatureWater MovementsModels, TheoreticalThermal Conductivity

Stichwörter der Autor:innen

Groundwater circulation wellGroundwater contamination remediationNumerical simulationSandbox experimentsThermal conductive heating

Substanzen

Water Pollutants, ChemicalNitrobenzenesnitrobenzene

Autor:innen und Institutionen

  • State Key Laboratory of Geohazard Prevention and Geoenvironment Protection (Chengdu University of Technology), Chengdu 610059, China; College of Environment and Civil Engineering, Chengdu University of Technology, Cheng…
  • Sichuan Academy of Environmental Policy and Planning, Chengdu 610000, China.
  • State Key Laboratory of Geohazard Prevention and Geoenvironment Protection (Chengdu University of Technology), Chengdu 610059, China.
  • Eastern Institute of Technology, Ningbo 315200, China.

Förderung

  • National Key Research and Development Program of China
  • Natural Science Foundation of Sichuan Province
  • National Natural Science Foundation of China

Zitieren

APA

Hu, X., Hu, Y., Liu, C., Wang, W., Pu, S., Jiao, T., & Zheng, C. (2026). Enhanced performances of the coupled thermal conductive heating-groundwater circulation well approach. Journal of Contaminant Hydrology, 280, 104928. https://doi.org/10.1016/j.jconhyd.2026.104928

Vancouver

Hu X, Hu Y, Liu C, Wang W, Pu S, Jiao T, et al. Enhanced performances of the coupled thermal conductive heating-groundwater circulation well approach. Journal of Contaminant Hydrology. 2026;280:104928. doi:10.1016/j.jconhyd.2026.104928

BibTeX
@article{Hu2026,
  author = {Hu, Xinglu and Hu, Yue and Liu, Chuankun and Wang, Weijia and Pu, Shengyan and Jiao, Tong and Zheng, Chunmiao},
  title = {Enhanced performances of the coupled thermal conductive heating-groundwater circulation well approach},
  journal = {Journal of Contaminant Hydrology},
  year = {2026},
  volume = {280},
  pages = {104928},
  doi = {10.1016/j.jconhyd.2026.104928}
}