Impact of elevated temperature from water cooling system on contaminant transport in clay liners: A laboratory and numerical investigation
Journal of Contaminant Hydrology · 2025
DOI: 10.1016/j.jconhyd.2025.104572 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Contaminant Hydrology, 2025. Verfasst von Vihan Jayawardane und 3 weiteren Autor:innen. Beteiligte Einrichtung: Civil Engineering Department, School of Engineering, Monash University Malaysia, Jalan Lagoon Selatan, 47500 Bandar Sunway, Selangor Darul Ehsan, Mal…. Hauptthemen laut MEDLINE: Waste Disposal Facilities, Refuse Disposal, Hot Temperature, Water Pollutants, Chemical. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 59 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: Malaysia Ministry of Higher Education.
Abstract (Originalsprache)
In municipal solid waste landfills (MSWL), the center and peripheral regions of the basal compacted clay liner (CCL) often experience steady elevated temperatures due to waste biodegradation and cyclic temperatures similar to the seasonal atmospheric temperature patterns, respectively. In the present study, the negative effects of cyclic elevated temperatures on the desiccation behaviour of a MSWL basal CCL was examined by subjecting CCL samples to multiple wet-dry cycles with different drying temperatures. It was observed that the extent of desiccation cracking experienced by the CCL rose as the drying temperature and number of wet-dry cycles increased. The present study also assessed the effect of different thermoplastic cooling pipes on the reduction of temperature rise and desiccation experienced by CCLs exposed to constant elevated temperatures (CETs). It was observed that the introduction of thermoplastic cooling pipes led to a significant attenuation of the final temperature (FT) and desiccation magnitude along the CCL depth in the face of all applied CETs, irrespective of the cooling pipe material employed. A comprehensively analysis of the final temperature distributions within the entire CCL, coolant and sand layer surrounding the cooling pipe was also carried out via the conduction of a numerical simulation. Overall, the present study revealed the adverse effects imposed by cyclic elevated temperatures on a CCL and the potential that thermoplastic cooling pipes possess to successfully reduce the temperature rise and desiccation experienced by a CCL in the face of different CETs.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Civil Engineering Department, School of Engineering, Monash University Malaysia, Jalan Lagoon Selatan, 47500 Bandar Sunway, Selangor Darul Ehsan, Malaysia; Monash Climate-Resilient Infrastructure Research Hub (M-CRInfra…
- School of Engineering and Technology, Central Queensland University, 120 Spencer Street, Melbourne, Victoria 3000, Australia.
Förderung
- Malaysia Ministry of Higher Education
Zitieren
APA
Jayawardane, V., Widjaja, E. S., Anggraini, V., & Mirzababaei, M. (2025). Impact of elevated temperature from water cooling system on contaminant transport in clay liners: A laboratory and numerical investigation. Journal of Contaminant Hydrology. https://doi.org/10.1016/j.jconhyd.2025.104572
Vancouver
Jayawardane V, Widjaja ES, Anggraini V, Mirzababaei M. Impact of elevated temperature from water cooling system on contaminant transport in clay liners: A laboratory and numerical investigation. Journal of Contaminant Hydrology. 2025. doi:10.1016/j.jconhyd.2025.104572
BibTeX
@article{Jayawardane2025,
author = {Jayawardane, Vihan and Widjaja, Emmanuella Stephanie and Anggraini, Vivi and Mirzababaei, Mehdi},
title = {Impact of elevated temperature from water cooling system on contaminant transport in clay liners: A laboratory and numerical investigation},
journal = {Journal of Contaminant Hydrology},
year = {2025},
doi = {10.1016/j.jconhyd.2025.104572}
}
EUVIMED