Three-dimensional stereophotogrammetry for periocular tumors: Reproducibility and clinical feasibility
Journal of Cranio-Maxillofacial Surgery · 2026-06 · 54 (6) · 104547
DOI: 10.1016/j.jcms.2026.104547 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Cranio-Maxillofacial Surgery, 2026-06. Verfasst von Xincen Hou und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Ophthalmology, University of Cologne, Faculty of Medicine and University Hospital Cologne, Cologne, Germany; Department of Ophthalmolog…. Hauptthemen laut MEDLINE: Photogrammetry, Imaging, Three-Dimensional, Eyelid Neoplasms. Die Arbeit nennt 44 Literaturangaben. Gefördert von: China Scholarship Council.
Abstract (Originalsprache)
This study aimed to evaluate the intra- and inter-rater reproducibility of periocular tumor measurements using three-dimensional (3D) stereophotogrammetry and to explore its potential clinical feasibility in periocular tumor assessment. Standardized 3D facial images were obtained from 150 patients with a total of 175 periocular tumors using the Vectra M3 imaging system. Surface areas were independently measured by two raters. Intra- and inter-rater reliability were assessed using intraclass correlation coefficients (ICC), mean absolute deviation (MAD), technical error of measurement (TEM), relative error of measurement (REM), and relative TEM (rTEM). Key factors influencing measurement reliability were identified through LASSO regression and random forest analysis. Overall measurement reliability was excellent, with intra-rater and inter-rater ICCs of 0.998 and 0.974, respectively. The mean intra-rater and inter-rater MAD were 0.63 mm2 and 0.40 mm2, while TEMs were 2.29 mm2 and 7.81 mm2. Intra-rater and inter-rater REM values were 1.94% and 1.22%, respectively. Tumors >5 mm showed significantly higher reliability than tumors ≤5 mm (p = 0.010). Tumors with well-defined boundaries had superior reproducibility compared to those with unclear margins (p = 0.026). Localization influenced reliability, with lateral canthus tumors showing the highest consistency (p = 0.008). Tumor color also affected reliability, with brownish-black tumors exhibiting the greatest reproducibility (p = 0.021). Three-dimensional stereophotogrammetry demonstrated high reproducibility for periocular tumor assessment. These findings suggest its potential clinical applicability as an adjunctive tool to support preoperative planning and longitudinal monitoring.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Ophthalmology, University of Cologne, Faculty of Medicine and University Hospital Cologne, Cologne, Germany; Department of Ophthalmology, Qilu Hospital of Shandong University, Jinan, China.
- Department of Ophthalmology, University of Cologne, Faculty of Medicine and University Hospital Cologne, Cologne, Germany.
- Eye Center, Second Affiliated Hospital, Zhejiang University School of Medicine, Hangzhou, China; Zhejiang Provincial Key Laboratory of Ophthalmology, Hangzhou, China.
- Department of Ophthalmology, University of Cologne, Faculty of Medicine and University Hospital Cologne, Cologne, Germany; Eye Center, Second Affiliated Hospital, Zhejiang University School of Medicine, Hangzhou, China;…
- Department of Ophthalmology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430030, China. Electronic address: fwl900506@163.com.
- Department of Ophthalmology, University of Cologne, Faculty of Medicine and University Hospital Cologne, Cologne, Germany; Center for Integrated Oncology (CIO), Aachen-Bonn-Cologne-Duesseldorf, Cologne, Germany; Center…
Förderung
- China Scholarship Council
Zitieren
APA
Hou, X., Aretz, M. L., Guo, Y., Heindl, L. M., Fan, W., & Rokohl, A. C. (2026). Three-dimensional stereophotogrammetry for periocular tumors: Reproducibility and clinical feasibility. Journal of Cranio-Maxillofacial Surgery, 54(6), 104547. https://doi.org/10.1016/j.jcms.2026.104547
Vancouver
Hou X, Aretz ML, Guo Y, Heindl LM, Fan W, Rokohl AC. Three-dimensional stereophotogrammetry for periocular tumors: Reproducibility and clinical feasibility. Journal of Cranio-Maxillofacial Surgery. 2026;54(6):104547. doi:10.1016/j.jcms.2026.104547
BibTeX
@article{Hou2026,
author = {Hou, Xincen and Aretz, Marlis Leonie and Guo, Yongwei and Heindl, Ludwig M and Fan, Wanlin and Rokohl, Alexander C},
title = {Three-dimensional stereophotogrammetry for periocular tumors: Reproducibility and clinical feasibility},
journal = {Journal of Cranio-Maxillofacial Surgery},
year = {2026},
volume = {54},
number = {6},
pages = {104547},
doi = {10.1016/j.jcms.2026.104547}
}