A method for accuracy of placement analysis on radiolucent polyether-ether-keton facial implants: A case series
Journal of Cranio-Maxillofacial Surgery · 2024
DOI: 10.1016/j.jcms.2024.06.009 ↗Kurz gefasst
Fallbericht in der Zeitschrift Journal of Cranio-Maxillofacial Surgery, 2024. Verfasst von M C P Kortman und 5 weiteren Autor:innen. Beteiligte Einrichtung: University of Twente, Technical Medical Centre, Multi-Modality Medical Imaging (M3i), Faculty of Science & Technology, Enschede, the Netherlands. Hauptthemen laut MEDLINE: Benzophenones, Cone-Beam Computed Tomography, Ketones, Polyethylene Glycols. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 24 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Facial asymmetry is defined as a bilateral difference between facial components. Correction, often desired by the patient, can be performed with the aim of bone born patient-specific solid implants designed using 3D CAD software. This treatment is embedded in the daily practice of today's healthcare. However, an analysis of the implant's accuracy of placement has not been reported. This case series describes the accuracy analysis of bone born aesthetic facial implants manufactured out of polyether-ether-ketone (PEEK). The accuracy analysis was based on postoperative (cone beam) computed tomography ((CB)CT) data and preoperative 3D planning. The analysis showed a median entry point error of 0.7 mm (min: 0.1, max: 3.3, interquartile range: 0.78). The median maximal orientation error was 5.5° (min: 0.1, max: 36.8, interquartile range: 7.13). Both parameters showed an excellent intraobserver and interobserver agreement with an ICC above 0.84. The described cases show that the analysis method is an objective approach for determining the accuracy of PSI placement and indicates that these implants can be placed accurately on the osseous face.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- University of Twente, Technical Medical Centre, Multi-Modality Medical Imaging (M3i), Faculty of Science & Technology, Enschede, the Netherlands.
- Dpt of Oral and Maxillofacial Surgery, Martini Hospital, Groningen, the Netherlands.
- University of Twente, Technical Medical Centre, Robotics and Mechatronics, Faculty of Electrical Engineering Mathematics and Computer Science, Enschede, the Netherlands.
- 3D Lab, University of Groningen, University Medical Center Groningen, Groningen, the Netherlands; Dpt of Oral and Maxillofacial Surgery, University of Groningen, University Medical Centre Groningen, Groningen, the Nethe…
Zitieren
APA
Kortman, M. C. P., Jansma, J., Schepers, R. H., Slump, C. H., Merema, B. J., & Kraeima, J. (2024). A method for accuracy of placement analysis on radiolucent polyether-ether-keton facial implants: A case series. Journal of Cranio-Maxillofacial Surgery. https://doi.org/10.1016/j.jcms.2024.06.009
Vancouver
Kortman MCP, Jansma J, Schepers RH, Slump CH, Merema BJ, Kraeima J. A method for accuracy of placement analysis on radiolucent polyether-ether-keton facial implants: A case series. Journal of Cranio-Maxillofacial Surgery. 2024. doi:10.1016/j.jcms.2024.06.009
BibTeX
@article{Kortman2024,
author = {Kortman, M C P and Jansma, J and Schepers, R H and Slump, C H and Merema, B J and Kraeima, J},
title = {A method for accuracy of placement analysis on radiolucent polyether-ether-keton facial implants: A case series},
journal = {Journal of Cranio-Maxillofacial Surgery},
year = {2024},
doi = {10.1016/j.jcms.2024.06.009}
}
EUVIMED