Impact of Tissue Treatment and Leaflet Design on Fifth-Generation Balloon-Expandable Transcatheter Heart Valve Function
JACC: Cardiovascular Interventions · 2026-06 · 19 (11) · 1490-1501
DOI: 10.1016/j.jcin.2026.04.027 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift JACC: Cardiovascular Interventions, 2026-06. Verfasst von Julien Delarive und 19 weiteren Autor:innen. Beteiligte Einrichtung: Cardiovascular Translational Laboratory, Providence Research & Centre for Heart Lung Innovation, St. Paul's Hospital, Vancouver, British Columbia, Ca…. Hauptthemen laut MEDLINE: Heart Valve Prosthesis, Aortic Valve, Transcatheter Aortic Valve Replacement, Balloon Valvuloplasty. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 19 Literaturangaben.
Abstract (Originalsprache)
BACKGROUND: The SAPIEN 3 Ultra RESILIA (S3UR) transcatheter heart valve incorporates RESILIA-treated tissue and new commissural attachments in smaller valve sizes (20 and 23 mm). However, detailed performance data are lacking. OBJECTIVES: The aim of this study was to compare the S3UR with the SAPIEN 3 Ultra (S3U) transcatheter heart valve on the bench for transcatheter aortic valve replacement (TAVR), valve-in-valve (VIV), and redo-TAVR. METHODS: For index TAVR, 23- and 26-mm S3UR and S3U valves were compared at nominal size and during underexpansion. For VIV testing, 23-mm study valves were implanted in 25-mm Epic and 23-mm Mitroflow valves. Redo TAVR involved the implantation of 23-mm study valves in a 26-mm Evolut PRO valve. Hydrodynamic testing assessed mean gradient (MG), geometric orifice area, effective orifice area (EOA), opening index, pinwheeling, and leaflet motion. Histology, light transmission, micrometering, micro-computed tomography, and uniaxial tensile testing compared S3UR and S3U pericardium samples. Leaflet splay area was compared after leaflet modification. RESULTS: For index TAVR, 26-mm S3U and S3UR valves demonstrated comparable performance. In contrast, the 23-mm S3UR valve showed a lower MG (6.7 mm Hg vs 7.3 mm Hg) and larger EOA, geometric orifice area, and opening index than the 23-mm S3U valve, with MG differences increasing during underexpansion. In VIV, the 23-mm S3UR valve demonstrated systolic leaflet fluttering and hydrodynamics similar to those of S3U. In redo-TAVR, the S3UR showed a slightly lower MG and a marginally larger EOA. By micrometering, S3UR leaflet pericardium was thinner than S3U leaflet pericardium (0.28 ± 0.02 mm vs 0.36 ± 0.03 mm), but S3UR pericardium showed significantly higher tensile strength. S3UR leaflets splayed almost 40% less after modification with a central basal split. CONCLUSIONS: Commissural changes in smaller S3UR valves and thinner leaflets drive differences in hydrodynamics, leaflet motion, tensile strength, and leaflet splay after leaflet modification. This warrants further study.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Cardiovascular Translational Laboratory, Providence Research & Centre for Heart Lung Innovation, St. Paul's Hospital, Vancouver, British Columbia, Canada; Department of Cardiology, Lausanne University Hospital and Unive…
- St. Francis Hospital and Heart Centre, Roslyn, New York, USA.
- Cardiovascular Translational Laboratory, Providence Research & Centre for Heart Lung Innovation, St. Paul's Hospital, Vancouver, British Columbia, Canada; Centre for Translational Science & Medtech Innovation, Dilawri C…
- Cardiovascular Translational Laboratory, Providence Research & Centre for Heart Lung Innovation, St. Paul's Hospital, Vancouver, British Columbia, Canada.
- Centre for Translational Science & Medtech Innovation, Dilawri Cardiovascular Institute, Vancouver, British Columbia, Canada.
- St. Francis Hospital and Heart Centre, Roslyn, New York, USA; Department of Medicine, Mayo Clinic, Jacksonville, Florida, USA.
Zitieren
APA
Delarive, J., Khan, J. M., MacLeod, B., Lai, A., Kane, A., Jamieson, C., Dakroub, A. H., Gill, H., Chatfield, A. G., Loretz, L., Quine, E., Kazerooni, N. A., de la Fuente, A., Muller, O., Fournier, S., McCabe, J. M., Webb, J. G., Wood, D. A., Meier, D., & Sellers, S. L. (2026). Impact of Tissue Treatment and Leaflet Design on Fifth-Generation Balloon-Expandable Transcatheter Heart Valve Function. JACC: Cardiovascular Interventions, 19(11), 1490-1501. https://doi.org/10.1016/j.jcin.2026.04.027
Vancouver
Delarive J, Khan JM, MacLeod B, Lai A, Kane A, Jamieson C, et al. Impact of Tissue Treatment and Leaflet Design on Fifth-Generation Balloon-Expandable Transcatheter Heart Valve Function. JACC: Cardiovascular Interventions. 2026;19(11):1490-1501. doi:10.1016/j.jcin.2026.04.027
BibTeX
@article{Delarive2026,
author = {Delarive, Julien and Khan, Jaffar M and MacLeod, Brooke and Lai, Althea and Kane, Alison and Jamieson, Colin and Dakroub, Ali H and Gill, Hacina and Chatfield, Andrew G and Loretz, Lucca and Quine, Edward and Kazerooni, Nazanin Afsar and de la Fuente, Angela and Muller, Olivier and Fournier, Stephane and McCabe, James M and Webb, John G and Wood, David A and Meier, David and Sellers, Stephanie L},
title = {Impact of Tissue Treatment and Leaflet Design on Fifth-Generation Balloon-Expandable Transcatheter Heart Valve Function},
journal = {JACC: Cardiovascular Interventions},
year = {2026},
volume = {19},
number = {11},
pages = {1490--1501},
doi = {10.1016/j.jcin.2026.04.027}
}
EUVIMED