Impact of Procedural Differences on Bolus Thermodilution Method for Assessment of Coronary Microvascular Dysfunction
Catheterization and Cardiovascular Interventions · 2025-10 · 106 (4) · 2439-2447
DOI: 10.1002/ccd.70085 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Catheterization and Cardiovascular Interventions, online erschienen am 06.08.2025. Verfasst von Shojiro Hirano und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Internal Medicine, Division of Cardiovascular Medicine, Toho University, Tokyo, Japan. Hauptthemen laut MEDLINE: Microcirculation, Cardiac Catheterization, Cardiac Catheters, Coronary Vessels. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 17 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: The authors received no specific funding for this work..
Abstract (Originalsprache)
Background
The thermodilution technique, employing bolus injections to measure coronary flow reserve (CFR) and the index of microcirculatory resistance (IMR), is widely used to assess coronary microvascular function. However, the potential influence of catheter size and operator differences on these measurements has not been systematically evaluated.
Aims
This study aimed to evaluate the feasibility and consistency of thermodilution‐based CMD assessment with respect to different catheter sizes and operators.
Methods
A total of 320 coronary arteries were assessed using a 0.014‐inch pressure–temperature sensor‐tipped guidewire. The data set included both angiographically normal vessels and those with varying degrees of stenosis.
Results
Four cases using 4 Fr catheters and data from three of seven operators (due to insufficient case numbers) were excluded. No statistically significant differences in CFR or IMR values were observed among the four operators. Similarly, no significant differences were found between experienced and less‐experienced operators (CFR: 1.90 vs. 1.80, p = 0.178; IMR: 19.00 vs. 20.50, p = 0.968). In contrast, CFR values varied significantly by catheter size (5 Fr: 2.20; 6 Fr: 1.80; 7 Fr: 1.50; 8 Fr: 1.70; p < 0.001), whereas IMR remained unaffected. When catheter sizes were dichotomized (small: 5–6 Fr; large: 7–8 Fr), CFR was significantly higher in the small‐size group (1.95 vs. 1.65, p = 0.003), while IMR showed no significant difference (20.00 vs. 20.00, p = 0.239).
Conclusions
While the selection of larger catheter sizes may affect CFR with thermodilution, common sizes and operator techniques show consistent results in practice.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Internal Medicine, Division of Cardiovascular Medicine, Toho University, Tokyo, Japan.
- Department of Cardiovascular Medicine, Faculty of Medicine, Toho University Graduate School of Medicine, Tokyo, Japan.
ORCID-Profile: Shojiro Hirano, Takanori Ikeda
Förderung
- The authors received no specific funding for this work.
Zitieren
APA
Hirano, S., Yabe, T., Okubo, R., Amano, H., & Ikeda, T. (2025). Impact of Procedural Differences on Bolus Thermodilution Method for Assessment of Coronary Microvascular Dysfunction. Catheterization and Cardiovascular Interventions, 106(4), 2439-2447. https://doi.org/10.1002/ccd.70085
Vancouver
Hirano S, Yabe T, Okubo R, Amano H, Ikeda T. Impact of Procedural Differences on Bolus Thermodilution Method for Assessment of Coronary Microvascular Dysfunction. Catheterization and Cardiovascular Interventions. 2025;106(4):2439-2447. doi:10.1002/ccd.70085
BibTeX
@article{Hirano2025,
author = {Hirano, Shojiro and Yabe, Takayuki and Okubo, Ryo and Amano, Hideo and Ikeda, Takanori},
title = {Impact of Procedural Differences on Bolus Thermodilution Method for Assessment of Coronary Microvascular Dysfunction},
journal = {Catheterization and Cardiovascular Interventions},
year = {2025},
volume = {106},
number = {4},
pages = {2439--2447},
doi = {10.1002/ccd.70085}
}
EUVIMED