EUVIMEDEUVIMED entdecken
ÜbersichtsarbeitOpen Access · CC BY 4.0

Quantitative GC-NICI-MS and GC-NICI-MS/MS analysis by using isotopologs as internal standards: A tutorial review

Dimitrios Tsikas

Journal of Chromatography B · 2025

DOI: 10.1016/j.jchromb.2025.124648 ↗

Kurz gefasst

Übersichtsarbeit in der Zeitschrift Journal of Chromatography B, 2025. Verfasst von Dimitrios Tsikas. Beteiligte Einrichtung: Institute of Toxicology, Core Unit Proteomics, Hannover Medical School, 30623 Hannover, Germany. Electronic address: tsikas.dimitros@mh-hannover.de. Hauptthemen laut MEDLINE: Gas Chromatography-Mass Spectrometry, Tandem Mass Spectrometry, Isotopes. Die Arbeit wurde bisher 10-mal zitiert (Crossref) und nennt 49 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The use of analytes labelled with stable-isotopes of 2H, 13C, 15N, 17O and/or 18O, i.e., the isotopologs, as internal standards is unique and considered the Golden Standard is quantitative analyses based on mass spectrometry. However, the handling with isotopologs deserves a great extent of care and attentiveness from the very begin of the analytical process. Many issues need to be considered in order to create an analytical method that generates close-to-reality concentrations of a certain analyte or of group of analytes of the same or different chemical classes in complex biological samples. They including isotopic purity, stability through the entire analytical process including sampling, derivatization, ionization and collision-induced dissociation (CID). The present work deals specifically with the use of isotopologs as internal standards for the quantitative analysis of endogenous and exogenous substances in plasma, serum and urine samples. It focuses on GC-MS and GC-MS/MS, negative-ion chemical ionization (NICI) with methane as the reagent gas, and selected-ion monitoring (SIM) or selected-reaction monitoring (SRM) using argon as the collision gas. Special attention has been paid to purity of isotopologs, cross-contribution of analyte-internal standard, and stability of isotopologs during NICI and CID, to linearity of analyte-isotope detector response upon the analyte concentration. This tutorial review re-examines and discusses exemplarily previously reported validated GC-MS and GC-MS/MS methods, and gives recommendations regarding the handling with stable-isotope labelled analogs in quantitative analyses.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Gas Chromatography-Mass SpectrometryTandem Mass SpectrometryIsotopesHumansReference Standards

Stichwörter der Autor:innen

DerivatizationKinetic and chromatographic H/D isotope effectsNegative-ion chemical ionization

Substanzen

Isotopes

Autor:innen und Institutionen

  • Institute of Toxicology, Core Unit Proteomics, Hannover Medical School, 30623 Hannover, Germany. Electronic address: tsikas.dimitros@mh-hannover.de.

Zitieren

APA

Tsikas, D. (2025). Quantitative GC-NICI-MS and GC-NICI-MS/MS analysis by using isotopologs as internal standards: A tutorial review. Journal of Chromatography B. https://doi.org/10.1016/j.jchromb.2025.124648

Vancouver

Tsikas D. Quantitative GC-NICI-MS and GC-NICI-MS/MS analysis by using isotopologs as internal standards: A tutorial review. Journal of Chromatography B. 2025. doi:10.1016/j.jchromb.2025.124648

BibTeX
@article{Tsikas2025,
  author = {Tsikas, Dimitrios},
  title = {Quantitative GC-NICI-MS and GC-NICI-MS/MS analysis by using isotopologs as internal standards: A tutorial review},
  journal = {Journal of Chromatography B},
  year = {2025},
  doi = {10.1016/j.jchromb.2025.124648}
}
Kostenlos starten →