EUVIMEDEUVIMED entdecken
Crossref

Effect of a motion-correction algorithm on motion-related image quality in mid-diastolic CCTA using 320-detector row CT

Tomoya Takayanagi, Takeshi Kondo, Takehiro Arai, Tomonari Sano, Hideki Nagaoka

Journal of Cardiovascular Computed Tomography · 2026-08

DOI: 10.1016/j.jcct.2026.08.003 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Cardiovascular Computed Tomography, 2026-08. Verfasst von Tomoya Takayanagi und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, Takase Memorial Hospital, Gunma, Japan. Electronic address: goreds_go@yahoo.co.jp. Die Arbeit nennt 24 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Motion artifacts limit coronary CT angiography (CCTA) when mid-diastolic quiescence is short. RR-PQ estimates the low-motion interval available for reconstruction, whereas motion correction may improve image quality without changing cardiac physiology. PURPOSE: To primarily evaluate the incremental effect of Clear Motion Cardiac (CMC) compared with half-scan reconstruction and secondarily characterize the probability of diagnostic image quality across RR-PQ values and derive candidate operational RR-PQ values on a 0.24-s/rotation 320-detector row CT system. METHODS: In 1012 consecutive CCTA examinations, paired half-scan and CMC series were reconstructed from identical raw data. Motion was graded A-D (A/B diagnostic). McNemar tests compared paired rates; logistic models estimated diagnostic probability and candidate RR-PQ values. RESULTS: Diagnostic image quality increased from 841/1012 (83.1%) with half-scan to 939/1012 (92.8%) with CMC (p < 0.0001). Of 171 half-scan failures, 101 were rescued; degradation occurred in 3/1012. Benefit increased with heart rate and was greatest at ≥70 bpm. RR-PQ was strongly associated with the probability of diagnostic image quality; candidate values at 95% probability were 807 ms for half-scan and 739 ms for CMC. CONCLUSION: CMC improved diagnostic image quality, especially at higher heart rates and shorter RR-PQ. The derived values may aid workflow planning but are platform- and cohort-specific.

Schlagwörter

Stichwörter der Autor:innen

320-Detector row CTClear motion cardiacCoronary CT angiographyDiagnostic image qualityMotion artifactsRR–PQ interval

Autor:innen und Institutionen

  • Department of Radiology, Takase Memorial Hospital, Gunma, Japan. Electronic address: goreds_go@yahoo.co.jp.
  • Department of Cardiology, Jyuko-kai Central Hospital, Aichi, Japan.
  • Department of Radiology, Takase Memorial Hospital, Gunma, Japan.
  • Department of Cardiology, Takase Memorial Hospital, Gunma, Japan.

Zitieren

APA

Takayanagi, T., Kondo, T., Arai, T., Sano, T., & Nagaoka, H. (2026). Effect of a motion-correction algorithm on motion-related image quality in mid-diastolic CCTA using 320-detector row CT. Journal of Cardiovascular Computed Tomography. https://doi.org/10.1016/j.jcct.2026.08.003

Vancouver

Takayanagi T, Kondo T, Arai T, Sano T, Nagaoka H. Effect of a motion-correction algorithm on motion-related image quality in mid-diastolic CCTA using 320-detector row CT. Journal of Cardiovascular Computed Tomography. 2026. doi:10.1016/j.jcct.2026.08.003

BibTeX
@article{Takayanagi2026,
  author = {Takayanagi, Tomoya and Kondo, Takeshi and Arai, Takehiro and Sano, Tomonari and Nagaoka, Hideki},
  title = {Effect of a motion-correction algorithm on motion-related image quality in mid-diastolic CCTA using 320-detector row CT},
  journal = {Journal of Cardiovascular Computed Tomography},
  year = {2026},
  doi = {10.1016/j.jcct.2026.08.003}
}
Kostenlos starten →