Reliability and convergent validity of smartphone-based discrete and continuous measures of spinal kinematics in asymptomatic individuals
Journal of Bodywork and Movement Therapies · 2026-10 · 48 · 142-149
DOI: 10.1016/j.jbmt.2026.06.002 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Bodywork and Movement Therapies, 2026-10. Verfasst von G. Christe und 9 weiteren Autor:innen. Die Arbeit nennt 31 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Haute école Spécialisée de Suisse Occidentale, Schweizerischer Nationalfonds zur Förderung der Wissenschaftlichen Forschung.
Abstract (Originalsprache)
Background
This study aimed to evaluate the within- and between-session reliability and the convergent validity of a mobile application for measuring discrete and continuous parameters of spinal kinematics in real-life settings. As a secondary objective, we explored the impact of the number of repetitions on reliability.
Methods
Spinal kinematics was measured using the mobile application Digiback during two different sessions in 30 asymptomatic participants (50% male; 36.7 ± 14.07 years old). Within- and between-session reliability of discrete parameters was calculated using the Intraclass Correlation Coefficient (ICC), while reliability of the continuous data was calculated using pointwise ICC values over the time-normalized amplitude data curves. Convergent validity was analysed against one inertial sensor attached to the upper lumbar spine.
Results
Reliability of discrete parameters was demonstrated by ICCs above 0.75 for most parameters. Reducing the number of repetitions to three had a minimal impact on ICCs. Integrated ICCs of continuous parameters varied between 0.34 and 0.79 for the whole curve, and from 0.64 to 0.88 for the mid portion (20-80%) of the movement curve. Convergent validity of discrete parameters varied across movements, with higher validity for sagittal-plane angular amplitude and velocity.
Conclusions
This study supports the reliability of measuring discrete and continuous sagittal-plane parameters of spinal kinematics with a smartphone in asymptomatic individuals. Reducing the number of repetitions from five to three had minimal impact on reliability, supporting clinical feasibility. Convergent validity was demonstrated only for discrete parameters in the sagittal plane.
Förderung
- Haute école Spécialisée de Suisse Occidentale
- Schweizerischer Nationalfonds zur Förderung der Wissenschaftlichen Forschung
Zitieren
APA
Christe, G., Moulin, L., Cerrito, A., Aesch, A. V., Zucchinetti, E., Pruvot, H., Sedzik, N., Boyaci, B., Schmid, S., & Raileanu, L. (2026). Reliability and convergent validity of smartphone-based discrete and continuous measures of spinal kinematics in asymptomatic individuals. Journal of Bodywork and Movement Therapies, 48, 142-149. https://doi.org/10.1016/j.jbmt.2026.06.002
Vancouver
Christe G, Moulin L, Cerrito A, Aesch AV, Zucchinetti E, Pruvot H, et al. Reliability and convergent validity of smartphone-based discrete and continuous measures of spinal kinematics in asymptomatic individuals. Journal of Bodywork and Movement Therapies. 2026;48:142-149. doi:10.1016/j.jbmt.2026.06.002
BibTeX
@article{Christe2026,
author = {Christe, G. and Moulin, L. and Cerrito, A. and Aesch, A. von and Zucchinetti, E. and Pruvot, H. and Sedzik, N. and Boyaci, B. and Schmid, S. and Raileanu, L.},
title = {Reliability and convergent validity of smartphone-based discrete and continuous measures of spinal kinematics in asymptomatic individuals},
journal = {Journal of Bodywork and Movement Therapies},
year = {2026},
volume = {48},
pages = {142--149},
doi = {10.1016/j.jbmt.2026.06.002}
}
EUVIMED