EUVIMEDEUVIMED entdecken
Crossref

Reliability and concurrent validity of smartphone-based inclinometer applications for sagittal spinal curvature assessment

Esra Bayramoğlu Demirdöğen iD, Aslı Akıllı, Ruken Öncü, Emre Uğuz iD, Muhammed Fırat Aladağ iD, Tufan Ulcay, Özkan Görgülü

European Spine Journal · 02.11.2026

DOI: 10.1007/s00586-026-10483-5 ↗

Kurz gefasst

Fachartikel in der Zeitschrift European Spine Journal, online erschienen am 02.11.2026. Verfasst von Esra Bayramoğlu Demirdöğen und 6 weiteren Autor:innen. Beteiligte Einrichtung: Ahi Evran University, Kırşehir, Turkey. Die Arbeit nennt 24 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

To evaluate the same-day intra-rater reliability, 24–48-hour test–retest reliability, concurrent validity, and inter-device agreement of sagittal spinal alignment measurements obtained using iOS- and Android-based smartphone inclinometer applications and a conventional bubble inclinometer.

Methods

Sixty-three healthy young adults (32 males, 31 females; mean age, 20.3 ± 1.2 years) were assessed at five spinal regions using the three measurement methods. Measurements were repeated within the same session and 24–48 h later. Reliability was evaluated using intraclass correlation coefficients (ICC), standard error of measurement, and minimum detectable change (MDC). Concurrent validity and inter-device agreement were assessed using ICC(2,1), Pearson’s correlation, Lin’s concordance correlation coefficient (CCC), and Bland–Altman analysis.

Results

Same-day ICC values ranged from 0.758 to 0.884 for iOS, 0.541–0.921 for Android, and 0.727–0.871 for the bubble inclinometer. Test–retest reliability was lower, ranging from 0.469 to 0.702, 0.097–0.607, and 0.392–0.745, respectively. The lowest ICC occurred for Android at the sacrum (0.097). MDC₉₀ ranged from 7.11° to 14.46°, and CCC values from 0.512 to 0.888. Bland–Altman analysis showed systematic bias in several device–landmark comparisons, with the largest absolute bias at C7 for iOS versus bubble inclinometry (− 5.08°).

Conclusion

Measurement performance varied by device, anatomical landmark, and assessment interval. Same-day repeatability was higher than 24–48-hour test–retest reliability, and the MDC values indicate that small longitudinal changes should be interpreted cautiously. Smartphone-based inclinometry may be useful for same-session assessment, but the observed inter-device bias does not support routine interchangeability. Serial measurements should preferably use the same device, application, landmarks, and standardized protocol.

Schlagwörter

Stichwörter der Autor:innen

AgreementConcurrent validityInclinometerReliabilitySagittal spinal alignmentSmartphone

Autor:innen und Institutionen

  • Ahi Evran University, Kırşehir, Turkey.
  • Ankara Hacı Bayram Veli University, Ankara, Turkey.
  • Ahi Evran University, Kırşehir, Turkey. tufanulcay@gmail.com.

ORCID-Profile: Esra Bayramoğlu Demirdöğen, Emre Uğuz, Muhammed Fırat Aladağ

Zitieren

APA

Bayramoğlu Demirdöğen, E., Akıllı, A., Öncü, R., Uğuz, E., Aladağ, M. F., Ulcay, T., & Görgülü, Ö. (2026). Reliability and concurrent validity of smartphone-based inclinometer applications for sagittal spinal curvature assessment. European Spine Journal. https://doi.org/10.1007/s00586-026-10483-5

Vancouver

Bayramoğlu Demirdöğen E, Akıllı A, Öncü R, Uğuz E, Aladağ MF, Ulcay T, et al. Reliability and concurrent validity of smartphone-based inclinometer applications for sagittal spinal curvature assessment. European Spine Journal. 2026. doi:10.1007/s00586-026-10483-5

BibTeX
@article{BayramoluDemirden2026,
  author = {Bayramoğlu Demirdöğen, Esra and Akıllı, Aslı and Öncü, Ruken and Uğuz, Emre and Aladağ, Muhammed Fırat and Ulcay, Tufan and Görgülü, Özkan},
  title = {Reliability and concurrent validity of smartphone-based inclinometer applications for sagittal spinal curvature assessment},
  journal = {European Spine Journal},
  year = {2026},
  doi = {10.1007/s00586-026-10483-5}
}