Assessing hip proprioceptive accuracy in passive, active, and weighted flexion: Implications of joint position reproduction for clinical rehabilitation
Journal of Bodywork and Movement Therapies · 2026-07 · 47 · 514-518
DOI: 10.1016/j.jbmt.2026.05.004 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Bodywork and Movement Therapies, 2026-07. Verfasst von Wootaek Lim. Beteiligte Einrichtung: Department of Physical Therapy, Woosong University, Daejeon, Republic of Korea; Department of Digital Bio-Health Convergence, Woosong University, Dae…. Hauptthemen laut MEDLINE: Hip Joint, Proprioception, Range of Motion, Articular. Die Arbeit nennt 36 Literaturangaben. Gefördert von: Ministry of Education, Woosong University.
Abstract (Originalsprache)
BACKGROUND Joint position reproduction (JPR) is widely used as a proprioceptive assessment method to examine differences between a reference and an indicator angle. However, in daily activities, no prior reference is available to guide specific movements. Because the hip joint plays a critical role in gait and postural control, proprioceptive assessment of this joint is clinically important. OBJECTIVE This study aimed to analyze the effect of different intensities of muscle contraction on position error in the hip joint using a modified JPR approach. METHODS After identifying each participant's maximal range of motion (Max-ROM) of the hip joint in the supine position, 50% of the Max-ROM was set as the target angle. The estimated hip flexion angle to this target was measured under three conditions: passive hip flexion, active hip flexion, and active hip flexion with a 1-kg weight. Additionally, traditional JPR using contralateral reference was conducted. RESULTS Position errors under the four conditions were 4.8° (passive), 1.1° (active), -0.9° (active with additional weight), and -4.6° (traditional JPR). The traditional JPR method resulted in significantly different error than that measured at passive hip flexion. In contrast, both active and weighted active conditions demonstrated smaller position errors, indicating greater accuracy in JPR. CONCLUSION The modified JPR, which used the reference angle as a baseline rather than as a target angle, produced errors comparable to those observed in traditional JPR, suggesting its potential as a practical and effective method for proprioceptive assessment.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Physical Therapy, Woosong University, Daejeon, Republic of Korea; Department of Digital Bio-Health Convergence, Woosong University, Daejeon, Republic of Korea. Electronic address: wootaeklimpt@wsu.ac.kr.
Förderung
- Ministry of Education
- Woosong University
Zitieren
APA
Lim, W. (2026). Assessing hip proprioceptive accuracy in passive, active, and weighted flexion: Implications of joint position reproduction for clinical rehabilitation. Journal of Bodywork and Movement Therapies, 47, 514-518. https://doi.org/10.1016/j.jbmt.2026.05.004
Vancouver
Lim W. Assessing hip proprioceptive accuracy in passive, active, and weighted flexion: Implications of joint position reproduction for clinical rehabilitation. Journal of Bodywork and Movement Therapies. 2026;47:514-518. doi:10.1016/j.jbmt.2026.05.004
BibTeX
@article{Lim2026,
author = {Lim, Wootaek},
title = {Assessing hip proprioceptive accuracy in passive, active, and weighted flexion: Implications of joint position reproduction for clinical rehabilitation},
journal = {Journal of Bodywork and Movement Therapies},
year = {2026},
volume = {47},
pages = {514--518},
doi = {10.1016/j.jbmt.2026.05.004}
}
EUVIMED