EUVIMEDEUVIMED entdecken
Crossref

Joint position sense error in the hip and knee without reference to the joint angle

Wootaek Lim

Journal of Back and Musculoskeletal Rehabilitation · 2023

DOI: 10.3233/bmr-230129 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Back and Musculoskeletal Rehabilitation, 2023. Verfasst von Wootaek Lim. Beteiligte Einrichtung: Department of Physical Therapy, College of Health and Welfare, Woosong University, Daejeon, Korea. Hauptthemen laut MEDLINE: Knee Joint, Knee. Die Arbeit nennt 44 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Joint position reproduction measures the angle acuity of reference angle reproduction using an indicator angle. However, reference angles are often not available. OBJECTIVE: This study aimed to examine joint position sense at three different targeted joint angles, which were estimated from the maximum range of motion (maxROM) without a reference angle at each targeted joint angle. METHODS: The maxROM was measured in straight leg raise (SLR) and active knee extension (AKE) positions. In both positions, a targeted joint angle at 75% of the maxROM was assessed first, followed by that at 50% and 25% of the maxROM. A one-sample t-test was used to analyze differences between the targeted and reproduced angles in both positions. RESULTS: All reproduced angles significantly differed from the targeted angle in both SLR and AKE positions except for the reproduced angle measured at 75% maxROM. Overall, position errors in the AKE position were higher than those in the SLR position. CONCLUSIONS: Estimating the angle based on the maxROM without a matched reference angle may lead to significant discrepancies in comparison with the targeted joint angle. In clinical settings, if accurate reproduction of motions is required to improve proprioception, providing a reference angle might be helpful.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Knee JointKneeHumansProprioceptionRange of Motion, ArticularHip Joint

Stichwörter der Autor:innen

Joint flexibilitylower extremityproprioceptionrange of motion

Autor:innen und Institutionen

  • Department of Physical Therapy, College of Health and Welfare, Woosong University, Daejeon, Korea.
  • Department of Digital Bio-Health Convergence, College of Health and Welfare, Woosong University, Daejeon, Korea.

Zitieren

APA

Lim, W. (2023). Joint position sense error in the hip and knee without reference to the joint angle. Journal of Back and Musculoskeletal Rehabilitation. https://doi.org/10.3233/bmr-230129

Vancouver

Lim W. Joint position sense error in the hip and knee without reference to the joint angle. Journal of Back and Musculoskeletal Rehabilitation. 2023. doi:10.3233/bmr-230129

BibTeX
@article{Lim2023,
  author = {Lim, Wootaek},
  title = {Joint position sense error in the hip and knee without reference to the joint angle},
  journal = {Journal of Back and Musculoskeletal Rehabilitation},
  year = {2023},
  doi = {10.3233/bmr-230129}
}
Kostenlos starten →