Reliability of muscle thickness and muscle echo intensity evaluation of the posterior medial tibia in long-distance athletes using an ultrasound imaging device
Journal of Bodywork and Movement Therapies · 2024
DOI: 10.1016/j.jbmt.2024.02.035 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Bodywork and Movement Therapies, 2024. Verfasst von Shun Kosugi und 3 weiteren Autor:innen. Beteiligte Einrichtung: Kato orthopedic surgery, 1-397-1, Awanonishi, Gifu City, Gifu, 502-0006, Japan. Electronic address: 21s1051@g.iuhw.ac.jp. Hauptthemen laut MEDLINE: Ultrasonography, Muscle, Skeletal, Tibia. Die Arbeit nennt 15 Literaturangaben.
Abstract (Originalsprache)
OBJECTIVE: We aimed to verify the reliability of muscle thickness and luminance evaluation of the deep leg muscles using an ultrasound device. DESIGN: Cohort study. SETTING: Track and field, Participants: high school track and field long distance athletes (N = 10, female: 50.0%, age = 16.0 ± 2.8 years, BMI = 18.2 ± 2.3 kg/m2) PARTICIPANTS: This study included Japanese high school track and long-distance field athletes. MAIN OUTCOME MEASURES: The thickness and echo intensity of tibialis posterior, flexor digitorum longus, and soleus muscles in the posterior medial tibia were clarified. RESULTS: The echo intensity evaluation of the tibialis posterior muscle showed an additive error. CONCLUSION: The study suggested that the results could be clinically applied clinically, except for the evaluation of echo intensity of the posterior tibialis muscle.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Kato orthopedic surgery, 1-397-1, Awanonishi, Gifu City, Gifu, 502-0006, Japan. Electronic address: 21s1051@g.iuhw.ac.jp.
- International University of Health and Welfare, Narita Campus, 4-3, Kozunomori, Narita City, 286-8686, Japan.
Zitieren
APA
Kosugi, S., Kono, K., Ishida, T., & Nishida, Y. (2024). Reliability of muscle thickness and muscle echo intensity evaluation of the posterior medial tibia in long-distance athletes using an ultrasound imaging device. Journal of Bodywork and Movement Therapies. https://doi.org/10.1016/j.jbmt.2024.02.035
Vancouver
Kosugi S, Kono K, Ishida T, Nishida Y. Reliability of muscle thickness and muscle echo intensity evaluation of the posterior medial tibia in long-distance athletes using an ultrasound imaging device. Journal of Bodywork and Movement Therapies. 2024. doi:10.1016/j.jbmt.2024.02.035
BibTeX
@article{Kosugi2024,
author = {Kosugi, Shun and Kono, Kenichi and Ishida, Takeki and Nishida, Yusuke},
title = {Reliability of muscle thickness and muscle echo intensity evaluation of the posterior medial tibia in long-distance athletes using an ultrasound imaging device},
journal = {Journal of Bodywork and Movement Therapies},
year = {2024},
doi = {10.1016/j.jbmt.2024.02.035}
}
EUVIMED