Reliability of the split tibialis anterior muscle flap for tibial shaft coverage: a cadaveric injection study
European Journal of Orthopaedic Surgery & Traumatology · 22.05.2026 · 36 (1)
DOI: 10.1007/s00590-026-04783-1 ↗Kurz gefasst
Fachartikel in der Zeitschrift European Journal of Orthopaedic Surgery & Traumatology, online erschienen am 22.05.2026. Verfasst von Surasak Jitprapaikulsarn und 7 weiteren Autor:innen. Beteiligte Einrichtung: Buddhachinaraj Hospital, Phitsanulok, Thailand. Hauptthemen laut MEDLINE: Muscle, Skeletal, Surgical Flaps, Tibia, Tibial Fractures. Die Arbeit nennt 16 Literaturangaben.
Abstract (Originalsprache)
BACKGROUND: The vascular perfusion of a split tibialis anterior muscle (TAM) flap has not been specifically investigated. This cadaveric study was performed to evaluate the anatomical reliability of a split TAM flap using thermographic assessment and contrast injection. METHODS: Five paired fresh-frozen cadaveric lower-extremity specimens were included. A split TAM flap was elevated using a design of longitudinal lateral split with a medial muscular hinge. Flap dimensions were recorded. Heated water was injected through the popliteal artery, followed by thermographic assessment using a thermal imaging camera. Subsequently, contrast medium was injected, and the number of intramuscular perforators supplying the split flap was evaluated. RESULTS: The mean flap dimension was 3 × 13.5 cm² (range, 2.5-4 × 12-15 cm²). Thermographic assessment demonstrated a mean temperature difference of 18.6 °C between pre- and post-injection measurements. Following contrast injection, a mean of 4 intramuscular perforators was identified within each split TAM flap (range, 3-5). CONCLUSION: The split tibialis anterior muscle flap demonstrates reliable vascular perfusion and represents a viable anatomical option for coverage of narrow anteromedial defects of the tibial shaft.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Buddhachinaraj Hospital, Phitsanulok, Thailand.
- Department of Orthopedics, Chiang Mai University, Chiang Mai, Thailand. jirachart.kraisarin@cmu.ac.th.
- Orthopedic Center of Excellence, Department of Orthopedics, Bangkok Hospital Chiang Mai, Chiang Mai, Thailand.
- Department of Orthopedics, Chiang Mai University, Chiang Mai, Thailand.
- Department of Orthopedics, Chonburi Hospital, Chon Buri, Thailand.
Zitieren
APA
Jitprapaikulsarn, S., Kraisarin, J., Apivatthakakul, T., Lertvilai, P., Sengpanich, P., Gromprasit, A., Sitti, K., & Leangtanom, P. (2026). Reliability of the split tibialis anterior muscle flap for tibial shaft coverage: a cadaveric injection study. European Journal of Orthopaedic Surgery & Traumatology, 36(1). https://doi.org/10.1007/s00590-026-04783-1
Vancouver
Jitprapaikulsarn S, Kraisarin J, Apivatthakakul T, Lertvilai P, Sengpanich P, Gromprasit A, et al. Reliability of the split tibialis anterior muscle flap for tibial shaft coverage: a cadaveric injection study. European Journal of Orthopaedic Surgery & Traumatology. 2026;36(1). doi:10.1007/s00590-026-04783-1
BibTeX
@article{Jitprapaikulsarn2026,
author = {Jitprapaikulsarn, Surasak and Kraisarin, Jirachart and Apivatthakakul, Theerachai and Lertvilai, Pasin and Sengpanich, Pasit and Gromprasit, Arthit and Sitti, Kittipop and Leangtanom, Panachol},
title = {Reliability of the split tibialis anterior muscle flap for tibial shaft coverage: a cadaveric injection study},
journal = {European Journal of Orthopaedic Surgery & Traumatology},
year = {2026},
volume = {36},
number = {1},
doi = {10.1007/s00590-026-04783-1}
}
EUVIMED