Development of an Electronic Clinical Quality Measure for Excessive Radiation Dose or Inadequate Image Quality in Diagnostic CT in Adults
Journal of the American College of Radiology · 2026-11
DOI: 10.1016/j.jacr.2026.09.021 ↗Kurz gefasst
Übersichtsarbeit in der Zeitschrift Journal of the American College of Radiology, 2026-11. Verfasst von Rebecca Smith-Bindman und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Epidemiology and Biostatistics, University of California, San Francisco, San Francisco, California; Department of Obstetrics, Gynecolog…. Die Arbeit nennt 44 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: Patient-Centered Outcomes Research Institute, Centers for Medicare and Medicaid Services.
Abstract (Originalsprache)
The Excessive Radiation Dose or Inadequate Image Quality for Diagnostic CT in Adults (ExRad) measure is the first automated radiology outcome measure adopted by CMS. We describe its development, specification, calculation, and adoption. Beginning in 2018, the measure was developed under a CMS cooperative agreement following the Measures Management System Blueprint, with oversight from a multidisciplinary Technical Expert Panel. ExRad evaluates each adult diagnostic CT examination in three steps. First, the examination is assigned to 1 of 19 CT categories defined by anatomic region and clinical indication using International Classification of Diseases, 10th Revision, Clinical Modification and Current Procedural Terminology codes. Second, size-adjusted radiation dose and image noise are computed from the DICOM dose report and pixel data; because clinical and radiology data reside in separate systems, translation software inside the hospital firewall performs the linkage and calculations automatically. Third, dose and noise are compared with category-specific thresholds derived from a reader study in which 125 radiologists rated the image quality of 734 CT examinations. An examination is out of range if either value exceeds its threshold, and the measure score is the percentage of eligible examinations that are out of range. Testing across 32 facilities in eight health systems confirmed the availability, accuracy, validity, and reproducibility of all data elements, and the National Quality Forum endorsed the measure in 2021. CMS adopted ExRad in 2023 into hospital inpatient, hospital outpatient, and clinician quality reporting programs, with voluntary reporting beginning in 2025. It is the sole outcome measure in the Diagnostic Radiology MIPS (Merit-Based Incentive Payment System) Value Pathway.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Epidemiology and Biostatistics, University of California, San Francisco, San Francisco, California; Department of Obstetrics, Gynecology, and Reproductive Sciences, University of California, San Francisco,…
- Department of Epidemiology and Biostatistics, University of California, San Francisco, San Francisco, California; Department of Epidemiology and Biostatistics, University of California, San Francisco, San Francisco, Cal…
- Alara Imaging, Inc, Westport, Connecticut; Department of Radiology and Biomedical Imaging, University of California, San Francisco, San Francisco, California.
- Alara Imaging, Inc, Westport, Connecticut.
- Departments of Radiology, Medical Physics, and Biomedical Engineering, University of Wisconsin-Madison, Madison, Wisconsin.
- Formerly with CMS, Center for Clinical Standards and Quality, Quality Measurement and Value-based Incentives Group, Baltimore, Maryland.
Förderung
- Patient-Centered Outcomes Research Institute
- Centers for Medicare and Medicaid Services
Zitieren
APA
Smith-Bindman, R., Bindman, A. B., Kohli, M. D., Stewart, C., Szczykutowicz, T. P., Kline, R. M., & Romano, P. S. (2026). Development of an Electronic Clinical Quality Measure for Excessive Radiation Dose or Inadequate Image Quality in Diagnostic CT in Adults. Journal of the American College of Radiology. https://doi.org/10.1016/j.jacr.2026.09.021
Vancouver
Smith-Bindman R, Bindman AB, Kohli MD, Stewart C, Szczykutowicz TP, Kline RM, et al. Development of an Electronic Clinical Quality Measure for Excessive Radiation Dose or Inadequate Image Quality in Diagnostic CT in Adults. Journal of the American College of Radiology. 2026. doi:10.1016/j.jacr.2026.09.021
BibTeX
@article{SmithBindman2026,
author = {Smith-Bindman, Rebecca and Bindman, Andrew B and Kohli, Marc D and Stewart, Carly and Szczykutowicz, Timothy P and Kline, Ronald M and Romano, Patrick S},
title = {Development of an Electronic Clinical Quality Measure for Excessive Radiation Dose or Inadequate Image Quality in Diagnostic CT in Adults},
journal = {Journal of the American College of Radiology},
year = {2026},
doi = {10.1016/j.jacr.2026.09.021}
}
EUVIMED