Variability Among Radiologists in Interpreting Low-Dose CT Lung Cancer Screens
Journal of the American College of Radiology · 2026
DOI: 10.1016/j.jacr.2026.08.006 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of the American College of Radiology, 2026. Verfasst von Paul F Pinsky und 12 weiteren Autor:innen. Beteiligte Einrichtung: Chief, Early Detection Branch, Division of Cancer Prevention, National Cancer Institute, Bethesda, Maryland. Electronic address: pp4f@nih.gov. Hauptthemen laut MEDLINE: Lung Neoplasms, Tomography, X-Ray Computed, Radiologists, Early Detection of Cancer. Die Arbeit nennt 18 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: Intramural NIH HHS.
Abstract (Originalsprache)
BACKGROUND: Lung cancer screening (LCS) with low-dose CT (LDCT) reduces lung cancer mortality, but false-positive tests remain a concern. Radiologist variability in interpreting LDCT scans may contribute to higher false-positive rates (FPRs). METHODS: Radiologists were identified from the LCS registry maintained by the ACR. Registry data were merged with Medicare files to create an LCS registry-Medicare database. Radiologists with ≥50 baseline or ≥50 postbaseline LDCT screens in the database were included in the analysis. The sensitivity and FPR were defined as the proportion of positive (Lung CT Screening Reporting and Data System 3-4) screens among those with and without a lung cancer diagnosis, respectively. Distributions, including median and interquartile range, of radiologists' FPRs were evaluated based on observed data and mixed-effects models, in which the radiologist was the random effect. Sensitivity was computed on an aggregate level based on radiologists' FPR quartiles. RESULTS: In all, 1,130 radiologists read ≥50 baseline screens, and 935 read ≥50 postbaseline screens. Median (interquartile range) FPR for baseline screens was 15.9% (11.3%-21.8%) and 16.3% (11.8%-21.8%) based on observed data and the mixed-effects model, respectively. Corresponding values for postbaseline screens were 8.5% (5.7%-12.8%) and 8.8% (6.3%-11.8%). Sensitivity increased significantly with radiologist FPR quartile for baseline and postbaseline screens. For baseline screens, radiologists in the lower two FPR quartiles had aggregate FPR and sensitivity of 10.9% and 89.6%, respectively, versus 24.1% and 94.4% for radiologists in the upper two quartiles. CONCLUSIONS: Variability in radiologists' FPRs with LDCT screening was high. Higher FPRs were associated with increased sensitivity rates.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Chief, Early Detection Branch, Division of Cancer Prevention, National Cancer Institute, Bethesda, Maryland. Electronic address: pp4f@nih.gov.
- University of Michigan, Ann Arbor, Michigan; Chair, ACR Committee on Lung Cancer Screening.
- Medical University of South Carolina, Charleston, South Carolina.
- Baptist Medical Center, Memphis, Tennessee.
- University of Washington, Seattle, Washington.
- National Cancer Institute, Bethesda, Maryland.
Förderung
- Intramural NIH HHS
Zitieren
APA
Pinsky, P. F., Kazerooni, E., Silvestri, G., Osarogiagbon, R. U., Farjah, F., Miller, E., Enewold, L., Henderson, L., Durham, D., Smith, R. A., Connor, P., Ward, A., & Doria-Rose, V. P. (2026). Variability Among Radiologists in Interpreting Low-Dose CT Lung Cancer Screens. Journal of the American College of Radiology. https://doi.org/10.1016/j.jacr.2026.08.006
Vancouver
Pinsky PF, Kazerooni E, Silvestri G, Osarogiagbon RU, Farjah F, Miller E, et al. Variability Among Radiologists in Interpreting Low-Dose CT Lung Cancer Screens. Journal of the American College of Radiology. 2026. doi:10.1016/j.jacr.2026.08.006
BibTeX
@article{Pinsky2026,
author = {Pinsky, Paul F and Kazerooni, Ella and Silvestri, Gerard and Osarogiagbon, Raymond U and Farjah, Farhood and Miller, Eric and Enewold, Lindsey and Henderson, Louise and Durham, Danielle and Smith, Robert A and Connor, Philip and Ward, Andrew and Doria-Rose, V Paul},
title = {Variability Among Radiologists in Interpreting Low-Dose CT Lung Cancer Screens},
journal = {Journal of the American College of Radiology},
year = {2026},
doi = {10.1016/j.jacr.2026.08.006}
}
EUVIMED