EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Safety and Efficacy of Transvenous Lead Extraction Using a Right-Sided Approach

Joe Demian, Thomas Callahan, David O Martin, Arshneel Kochar, Pasquale Santangeli, Tyler Taigen, Medhat Farwati, Chadi Tabaja, Mohammad Kanj, Bryan Baranowski, Ayman A Hussein, Mina Chung und 3 weitere

JACC: Clinical Electrophysiology · 2026-11

DOI: 10.1016/j.jacep.2026.09.006 ↗

Kurz gefasst

Fachartikel in der Zeitschrift JACC: Clinical Electrophysiology, 2026-11. Verfasst von Joe Demian und 14 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiovascular Medicine, Cardiac Electrophysiology Section, Cleveland Clinic, Cleveland, Ohio, USA. Die Arbeit nennt 19 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Despite extensive experience with transvenous lead extraction (TLE) overall, outcomes for systems implanted on the right chest remain underexplored, largely because of their low incidence. OBJECTIVES: The objective was to evaluate whether system laterality influences TLE outcomes. METHODS: Using our institutional, prospectively maintained ExTRACT registry, we analyzed all consecutive patients undergoing TLE procedures at the Cleveland Clinic between 1996 and 2022. Patients were categorized by system laterality. Baseline characteristics, procedural characteristics, and complications were assessed. Multivariable logistic regression models evaluated the association between right-sided TLE and adverse events. RESULTS: Among 4,989 patients, 494 (9.9%) had right-sided and 4,495 (90.1%) had left-sided TLE. Compared with left-sided cases, right-sided cases had longer total lead dwell times (13.83 vs 9.26 years, P < 0.001) and were more likely to be extracted because of infection (47.57% vs 39.71%, P = 0.001). Fluoroscopy time was longer (15.95 vs 12.1 minutes; P < 0.001), and femoral workstation use more frequent (7.89% vs 4.05%, P < 0.001), yet complete extraction was lower (94.53% vs 96.44%, P = 0.034). Right-sided TLE had higher rates of sternotomy (2.83% vs 1.25%, P = 0.004) and superior vena cava or right atrial tear/perforation (2.49% vs 1.10%, P = 0.009). Thirty-day mortality was low and comparable (0.61% vs 0.47%, P = 0.727). Multivariable regression showed that right-sided TLE was associated with higher odds of sternotomy (OR = 1.92, 95% CI: 1.01-3.46, P = 0.037) and superior vena cava or right atrial tear/perforation (OR = 2.02, 95% CI: 1.01-3.78, P = 0.037). CONCLUSIONS: Right-sided TLE is associated with a lower rate of complete extraction and increased procedural risk, particularly sternotomy and major vascular injury, compared with left-sided TLE. These findings should be carefully weighed when implanting or extracting right-sided systems.

Schlagwörter

Stichwörter der Autor:innen

cardiac implantable electronic deviceslead managementright atrial perforationright-sided extractionsternotomysuperior vena cava injury

Autor:innen und Institutionen

  • Department of Cardiovascular Medicine, Cardiac Electrophysiology Section, Cleveland Clinic, Cleveland, Ohio, USA.
  • Department of Cardiovascular Medicine, Cardiac Electrophysiology Section, Cleveland Clinic, Cleveland, Ohio, USA. Electronic address: younisa@ccf.org.

Zitieren

APA

Demian, J., Callahan, T., Martin, D. O., Kochar, A., Santangeli, P., Taigen, T., Farwati, M., Tabaja, C., Kanj, M., Baranowski, B., Hussein, A. A., Chung, M., Saliba, W., Wazni, O. M., & Younis, A. (2026). Safety and Efficacy of Transvenous Lead Extraction Using a Right-Sided Approach. JACC: Clinical Electrophysiology. https://doi.org/10.1016/j.jacep.2026.09.006

Vancouver

Demian J, Callahan T, Martin DO, Kochar A, Santangeli P, Taigen T, et al. Safety and Efficacy of Transvenous Lead Extraction Using a Right-Sided Approach. JACC: Clinical Electrophysiology. 2026. doi:10.1016/j.jacep.2026.09.006

BibTeX
@article{Demian2026,
  author = {Demian, Joe and Callahan, Thomas and Martin, David O and Kochar, Arshneel and Santangeli, Pasquale and Taigen, Tyler and Farwati, Medhat and Tabaja, Chadi and Kanj, Mohammad and Baranowski, Bryan and Hussein, Ayman A and Chung, Mina and Saliba, Walid and Wazni, Oussama M and Younis, Arwa},
  title = {Safety and Efficacy of Transvenous Lead Extraction Using a Right-Sided Approach},
  journal = {JACC: Clinical Electrophysiology},
  year = {2026},
  doi = {10.1016/j.jacep.2026.09.006}
}
Kostenlos starten →