EUVIMEDEUVIMED entdecken
Multizentrische Studie

Impact of Device Compression on Peridevice Leak After Left Atrial Appendage Closure

Vincenzo Mirco La Fazia, Roberto Galea, Domenico Giovanni Della Rocca, Carola Gianni, Antanas Gasys, Sanghamitra Mohanty, Raouf Madhkour, Nicola Pierucci, Prem Geeta Torlapati, Konstantina Chalkou, Gaetano Chiricolo, Caroline Chong-Nguyen und 5 weitere

JACC: Clinical Electrophysiology · 2025-12 · 11 (12) · 2742-2753

DOI: 10.1016/j.jacep.2025.08.014 ↗

Kurz gefasst

Multizentrische Studie in der Zeitschrift JACC: Clinical Electrophysiology, 2025-12. Verfasst von Vincenzo Mirco La Fazia und 16 weiteren Autor:innen. Beteiligte Einrichtung: Texas Cardiac Arrhythmia Institute, St David's Medical Center, Austin, Texas, USA. Hauptthemen laut MEDLINE: Atrial Appendage, Atrial Fibrillation, Postoperative Complications, Septal Occluder Device. Die Arbeit wurde bisher 19-mal zitiert (Crossref) und nennt 35 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Left atrial appendage closure (LAAC) is an established therapeutic strategy to prevent ischemic stroke in selected patients with atrial fibrillation. However, residual peridevice leaks (PDLs) post-LAAC remain a critical concern. OBJECTIVES: This study sought to assess the clinical impact of Watchman FLX device overcompression. METHODS: Data on consecutive patients undergoing a transesophageal echocardiography (TEE)-guided LAAC between 2020 and 2023 in 2 high-LAAC volume centers were collected and patients with a device compression higher (overcompression group) or lower (normal compression group) than 30% as evaluated by procedural TEE were compared in terms of procedural complications, composite of cardiovascular death, ischemic stroke, or systemic embolism, and PDL at TEE follow-up. RESULTS: This study included 61 overcompression and 175 normal compression patients. Baseline and procedural characteristics did not differ between the 2 groups. Both composite of procedural complications (1.6% vs 1.7%; P = 0.968) and of cardiovascular death, ischemic stroke, or systemic embolism during follow-up (9.8% vs 12%; P = 0.971) did not significantly differ between the 2 groups. At 2-month TEE follow-up, the rate of residual PDL was significantly lower in the overcompression group (8.2% vs 32.6%; P < 0.001). At the multivariate analysis, the device compression rate was the only variable independently associated to risk of PDL at TEE follow-up (adjusted OR: 0.935; 95% CI: 0.927-0.948; P = 0.003). CONCLUSIONS: In this dual-center cohort of TEE-guided LAAC, the overcompression group was independently associated to a higher rate of LAA occlusion at TEE follow-up.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Atrial AppendageAtrial FibrillationPostoperative ComplicationsSeptal Occluder DeviceHumansMaleFemaleAgedEchocardiography, TransesophagealAged, 80 and overMiddle AgedRetrospective StudiesIschemic StrokeLeft Atrial Appendage Closure

Stichwörter der Autor:innen

Watchman FLXatrial fibrillationdevice compressionleft atrial appendage occlusionperidevice leak

Autor:innen und Institutionen

  • Texas Cardiac Arrhythmia Institute, St David's Medical Center, Austin, Texas, USA.
  • Department of Cardiology, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland; Department of Cardiology, Hospital Centre of Biel, Biel, Switzerland.
  • Heart Rhythm Management Centre, Brussels, Belgium.
  • Department of Cardiology, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland.
  • Department of Clinical Research, University of Bern, Bern, Switzerland.
  • Department of Biomedicine and Prevention, Tor Vergata University of Rome, Rome, Italy.

Zitieren

APA

La Fazia, V. M., Galea, R., Della Rocca, D. G., Gianni, C., Gasys, A., Mohanty, S., Madhkour, R., Pierucci, N., Torlapati, P. G., Chalkou, K., Chiricolo, G., Chong-Nguyen, C., Horton, R., Al-Ahmad, A., Di Biase, L., Räber, L., & Natale, A. (2025). Impact of Device Compression on Peridevice Leak After Left Atrial Appendage Closure. JACC: Clinical Electrophysiology, 11(12), 2742-2753. https://doi.org/10.1016/j.jacep.2025.08.014

Vancouver

La Fazia VM, Galea R, Della Rocca DG, Gianni C, Gasys A, Mohanty S, et al. Impact of Device Compression on Peridevice Leak After Left Atrial Appendage Closure. JACC: Clinical Electrophysiology. 2025;11(12):2742-2753. doi:10.1016/j.jacep.2025.08.014

BibTeX
@article{LaFazia2025,
  author = {La Fazia, Vincenzo Mirco and Galea, Roberto and Della Rocca, Domenico Giovanni and Gianni, Carola and Gasys, Antanas and Mohanty, Sanghamitra and Madhkour, Raouf and Pierucci, Nicola and Torlapati, Prem Geeta and Chalkou, Konstantina and Chiricolo, Gaetano and Chong-Nguyen, Caroline and Horton, Rodney and Al-Ahmad, Amin and Di Biase, Luigi and Räber, Lorenz and Natale, Andrea},
  title = {Impact of Device Compression on Peridevice Leak After Left Atrial Appendage Closure},
  journal = {JACC: Clinical Electrophysiology},
  year = {2025},
  volume = {11},
  number = {12},
  pages = {2742--2753},
  doi = {10.1016/j.jacep.2025.08.014}
}
Kostenlos starten →