Intracardiac Echocardiography for the Detection of Arrhythmogenic Periaortic Ventricular Tachycardia Substrate
JACC: Clinical Electrophysiology · 2025-11 · 11 (11) · 2352-2364
DOI: 10.1016/j.jacep.2025.06.012 ↗Kurz gefasst
Fachartikel in der Zeitschrift JACC: Clinical Electrophysiology, 2025-11. Verfasst von Naohiko Sahara und 14 weiteren Autor:innen. Beteiligte Einrichtung: The University of Arizona College of Medicine-Phoenix, Banner-University Medical Center Phoenix, Phoenix, Arizona, USA. Hauptthemen laut MEDLINE: Tachycardia, Ventricular, Echocardiography. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 26 Literaturangaben.
Abstract (Originalsprache)
BACKGROUND: There is no established imaging technique to detect and diagnose periaortic scar, an increasingly prevalent and challenging substrate referred for ventricular tachycardia (VT) ablation. We hypothesized that wall thinning detected with intracardiac echocardiography (ICE) can identify periaortic arrhythmogenic substrate (PAS) in patients with structural heart disease. OBJECTIVES: This study sought to validate a new method of identifying PAS using ICE in comparison with electro-anatomic mapping and cardiac magnetic resonance (CMR). METHODS: A total of 84 VT ablation patients were analyzed (87% male, median age 72 years [Q1-Q3: 63-75 years], 61% with nonischemic cardiomyopathy) and categorized into 2 groups: PAS+ (n = 29) and PAS- (n = 55) based on voltage-defined scar and deceleration zones. Wall thickness of the basal anterior septum was measured by ICE and CMR at a standardized distance from the left ventricular ostium in diastole by an independent core lab. In 43 patients with CMR, correlation with late gadolinium enhancement (LGE) in the basal anterior septum was also assessed. RESULTS: A significant difference in wall thickness measured at 1 cm from the left ventricular ostium with ICE was observed between PAS+ and PAS- patients (0.57 cm [Q1-Q3: 0.51-0.65 cm] vs 0.72 cm [Q1-Q3: 0.65-0.79 cm]; P < 0.001). Wall thickness by ICE had higher diagnostic performance than CMR, with only 50% of PAS+ patients exhibiting LGE. At a cutoff of
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- The University of Arizona College of Medicine-Phoenix, Banner-University Medical Center Phoenix, Phoenix, Arizona, USA.
- Abbott Laboratories, Abbott Park, Illinois, USA.
- The University of Arizona College of Medicine-Phoenix, Banner-University Medical Center Phoenix, Phoenix, Arizona, USA. Electronic address: rodericktung@arizona.edu.
Zitieren
APA
Sahara, N., Shinoda, Y., Yeneneh, B., Gideon, P., Morris, M. F., Katrapati, P., Shatz, N., Bai, R., Martinez, J., Liao, Y., Shatz, D. Y., Zawaneh, M. S., Su, W., Weiss, J. P., & Tung, R. (2025). Intracardiac Echocardiography for the Detection of Arrhythmogenic Periaortic Ventricular Tachycardia Substrate. JACC: Clinical Electrophysiology, 11(11), 2352-2364. https://doi.org/10.1016/j.jacep.2025.06.012
Vancouver
Sahara N, Shinoda Y, Yeneneh B, Gideon P, Morris MF, Katrapati P, et al. Intracardiac Echocardiography for the Detection of Arrhythmogenic Periaortic Ventricular Tachycardia Substrate. JACC: Clinical Electrophysiology. 2025;11(11):2352-2364. doi:10.1016/j.jacep.2025.06.012
BibTeX
@article{Sahara2025,
author = {Sahara, Naohiko and Shinoda, Yasutoshi and Yeneneh, Beeletsega and Gideon, Philip and Morris, Michael F and Katrapati, Praneeth and Shatz, Nathaniel and Bai, Rong and Martinez, Jake and Liao, Yu and Shatz, Dalise Yi and Zawaneh, Michael S and Su, Wilber and Weiss, J Peter and Tung, Roderick},
title = {Intracardiac Echocardiography for the Detection of Arrhythmogenic Periaortic Ventricular Tachycardia Substrate},
journal = {JACC: Clinical Electrophysiology},
year = {2025},
volume = {11},
number = {11},
pages = {2352--2364},
doi = {10.1016/j.jacep.2025.06.012}
}
EUVIMED