Microvolt Activation Alternans Identifies Conduction Velocity Heterogeneity and the Entrance Site of Ischemic Ventricular Tachycardia
JACC: Clinical Electrophysiology · 2025
DOI: 10.1016/j.jacep.2025.02.014 ↗Kurz gefasst
Fachartikel in der Zeitschrift JACC: Clinical Electrophysiology, 2025. Verfasst von Nathan C Denham und 9 weiteren Autor:innen. Beteiligte Einrichtung: Peter Munk Cardiac Center, Division of Cardiology, University Health Network, Toronto, Ontario, Canada. Hauptthemen laut MEDLINE: Tachycardia, Ventricular, Myocardial Ischemia, Heart Conduction System, Body Surface Potential Mapping. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 28 Literaturangaben. Gefördert von: University of Toronto.
Abstract (Originalsprache)
BACKGROUND: Body surface microvolt QRS alternans has been shown to predict ventricular tachyarrhythmias in patients with cardiomyopathy; however, the mechanism is unclear. OBJECTIVES: The aim of this study was to determine the spatiotemporal relationship of beat-to-beat bipolar electrogram (EGM) activation alternans (AA) to the ventricular tachycardia (VT) circuit and to surface QRS alternans. METHODS: Intraoperative mapping during ventricular pacing and induced VT was performed in 9 patients with ischemic cardiomyopathy using a 112-bipole endocardial array. AA was quantified at EGM sites during pacing, timed to the surface QRS complex (intra vs post), correlated to local conduction velocity (CV), the location of the VT circuit, and surface QRS alternans. In silico modeling was performed to investigate the relationship between conduction disturbances and AA. RESULTS: Intra-QRS and post-QRS AA was present in 8 of 9 patients with similar frequency (4.6% [Q1-Q3: 2.8%-8.3%] vs 3.5% [Q1-Q3: 1.0%-4.7%]; P = 0.77) and magnitude (192 μV [Q1-Q3: 72-246 μV] vs 470 μV [Q1-Q3: 270-601 μV]; P = 0.158). The presence of intra-QRS AA strongly correlated with the entrance of the VT circuit compared with remote regions (OR: 6.8; 95% CI: 3.7-12.5; P < 0.001). CV heterogeneity was the primary determinant of intra-QRS AA magnitude, in which each 0.1 increase in heterogeneity correlated with a 31-μV (95% CI: 3-59 μV) magnitude increase (P = 0.032). Intra-QRS AA magnitude strongly correlated with surface QRS alternans magnitude (r = 0.92, P = 0.001). Computer modeling supported AA sites representing
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Peter Munk Cardiac Center, Division of Cardiology, University Health Network, Toronto, Ontario, Canada.
- IHU Liryc, Electrophysiology and Heart Modeling Institute, Fondation Bordeaux Université, Pessac, France; IMB UMR 5251, Université de Bordeaux, Talence, France.
- Peter Munk Cardiac Center, Division of Cardiology, University Health Network, Toronto, Ontario, Canada. Electronic address: vijay.chauhan@uhn.ca.
Förderung
- University of Toronto
Zitieren
APA
Denham, N. C., Suszko, A. M., Nemaire, M., Bhaskaran, A., Massé, S., Nanthakumar, K., Haïssaguerre, M., Downar, E., Vigmond, E., & Chauhan, V. S. (2025). Microvolt Activation Alternans Identifies Conduction Velocity Heterogeneity and the Entrance Site of Ischemic Ventricular Tachycardia. JACC: Clinical Electrophysiology. https://doi.org/10.1016/j.jacep.2025.02.014
Vancouver
Denham NC, Suszko AM, Nemaire M, Bhaskaran A, Massé S, Nanthakumar K, et al. Microvolt Activation Alternans Identifies Conduction Velocity Heterogeneity and the Entrance Site of Ischemic Ventricular Tachycardia. JACC: Clinical Electrophysiology. 2025. doi:10.1016/j.jacep.2025.02.014
BibTeX
@article{Denham2025,
author = {Denham, Nathan C and Suszko, Adrian M and Nemaire, Masimba and Bhaskaran, Abhishek and Massé, Stéphane and Nanthakumar, Kumaraswamy and Haïssaguerre, Michel and Downar, Eugene and Vigmond, Edward and Chauhan, Vijay S},
title = {Microvolt Activation Alternans Identifies Conduction Velocity Heterogeneity and the Entrance Site of Ischemic Ventricular Tachycardia},
journal = {JACC: Clinical Electrophysiology},
year = {2025},
doi = {10.1016/j.jacep.2025.02.014}
}