Transseptal Transition Patterns During Left Bundle Branch Area Lead Implantation
JACC: Clinical Electrophysiology · 2024-11 · 10 (11) · 2471-2484
DOI: 10.1016/j.jacep.2024.07.025 ↗Kurz gefasst
Fachartikel in der Zeitschrift JACC: Clinical Electrophysiology, 2024-11. Verfasst von Marek Jastrzębski und 7 weiteren Autor:innen. Beteiligte Einrichtung: First Department of Cardiology, Interventional Electrocardiology and Hypertension, Jagiellonian University, Medical College, Krakow, Poland; Electrop…. Hauptthemen laut MEDLINE: Electrocardiography. Die Arbeit wurde bisher 33-mal zitiert (Crossref) und nennt 17 Literaturangaben.
Abstract (Originalsprache)
BACKGROUND: Continuous deep septal pacing and signal recording during implantation of left bundle branch pacing (LBBP) lead enables to monitor beat-to-beat changes of electrocardiogram (ECG) and myocardial current of injury (COI) as the lead crosses the septum. OBJECTIVES: This study aimed to characterize patterns of continuous QRS, ST-T, and COI change for monitoring of the lead depth and instantaneous determination of the obtained capture type (LBBP vs left ventricular septal pacing [LVSP]). METHODS: The ECG and COI during lead implantation were scrutinized for sudden changes of V6 R-wave peak time, V1 initial and terminal R-wave amplitude, V3-V6 R-wave amplitude, repolarization pattern and S-wave amplitude in I, V5-V6, and COI drop. The sudden and gradual transition patterns were diagnosed depending on the presence or absence of the above beat-to-beat ECG phenomena, respectively. RESULTS: A total of 212 pacemaker recipients were analyzed; LBBP and LVSP were obtained in 77.4% and 22.6%, respectively. There were 4.7 ± 2.1 and 0.2 ± 0.6 beat-to-beat phenomena in LBBP and LVSP patients, respectively. The sudden transition pattern, recognized in 80.7%, had sensitivity and specificity for LBBP diagnosis of 98.8% and 81.2%, respectively. A sudden drop of COI (29.4 ± 8.5 mV to 12.8 ± 4.9 mV) was observed in 53.9% patients (LBBP was simultaneously obtained in 92.7%). CONCLUSIONS: Capture of left bundle branch during lead penetration is a beat-to-beat phenomenon. Two transseptal transition patterns were identified: 1) sudden, which is typical for obtaining LBBP; and 2) gradual, which is typical for obtaining LVSP. A sudden COI drop, a very observable phenomenon, also identified reaching the left subendocardial area.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- First Department of Cardiology, Interventional Electrocardiology and Hypertension, Jagiellonian University, Medical College, Krakow, Poland; Electrophysiology Laboratory, University Hospital in Krakow, Krakow, Poland. E…
- First Department of Cardiology, Interventional Electrocardiology and Hypertension, Jagiellonian University, Medical College, Krakow, Poland.
- Electrophysiology Laboratory, University Hospital in Krakow, Krakow, Poland.
- Cardiac Pacing Unit, Cardiology Department, University Hospital of Geneva, Geneva, Switzerland.
- Department of Cardiology, Third Faculty of Medicine, Charles University and University Hospital Kralovske Vinohrady, Prague, Czech Republic.
- Geisinger Heart Institute, Geisinger Commonwealth School of Medicine, Wilkes-Barre, Pennsylvania, USA.
Zitieren
APA
Jastrzębski, M., Kiełbasa, G., Moskal, P., Bednarek, A., Rajzer, M., Burri, H., Curila, K., & Vijayaraman, P. (2024). Transseptal Transition Patterns During Left Bundle Branch Area Lead Implantation. JACC: Clinical Electrophysiology, 10(11), 2471-2484. https://doi.org/10.1016/j.jacep.2024.07.025
Vancouver
Jastrzębski M, Kiełbasa G, Moskal P, Bednarek A, Rajzer M, Burri H, et al. Transseptal Transition Patterns During Left Bundle Branch Area Lead Implantation. JACC: Clinical Electrophysiology. 2024;10(11):2471-2484. doi:10.1016/j.jacep.2024.07.025
BibTeX
@article{Jastrzbski2024,
author = {Jastrzębski, Marek and Kiełbasa, Grzegorz and Moskal, Paweł and Bednarek, Agnieszka and Rajzer, Marek and Burri, Haran and Curila, Karol and Vijayaraman, Pugazhendhi},
title = {Transseptal Transition Patterns During Left Bundle Branch Area Lead Implantation},
journal = {JACC: Clinical Electrophysiology},
year = {2024},
volume = {10},
number = {11},
pages = {2471--2484},
doi = {10.1016/j.jacep.2024.07.025}
}
EUVIMED