Dynamic Changes of the S Wave in Lead V6: A Novel Visual Indicator for Left Bundle Branch Capture
Canadian Journal of Cardiology · 2025-12 · 41 (12) · 2592-2600
DOI: 10.1016/j.cjca.2025.08.351 ↗Kurz gefasst
Fachartikel in der Zeitschrift Canadian Journal of Cardiology, 2025-12. Verfasst von Shanshan Zhuo und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiology, Ningbo No. 2 Hospital, Ningbo, Zhejiang, China. Hauptthemen laut MEDLINE: Bundle-Branch Block, Electrocardiography, Cardiac Pacing, Artificial, Bundle of His. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 11 Literaturangaben. Gefördert von: Ningbo Science and Technology Bureau, Medical Scientific Research Foundation of Zhejiang Province, China.
Abstract (Originalsprache)
BACKGROUND: During the electrode screwing process in left bundle branch pacing (LBBP), the significance of the S wave in lead V6 remains elusive. In this study we analyzed the change of the S wave in lead V6 under different patterns of capture and explore its mechanisms. METHODS: Our study included 243 patients with selective LBBP (SLBBP). We used the continuous pacing technique and classified the electrophysiologic characteristics observed during the screwing process into 4 patterns: left ventricular septal pacing (LVSP), nonselective LBBP (NSLBBP) in low output and in lower output, and selective LBBP. The change of the S-wave morphology in lead V6 and R-wave peak time in leads V6 and V1 were evaluated according to these 4 patterns. RESULTS: In all 243 cases, the presence of S wave in V6 gradually increased in the 4 patterns as follows: 35.4% in LVSP, 77.0% in NSLBBP low output, 82.7% in NSLBBP lower output, and 97.9% in SLBBP. From the LVSP to the NSLBBP (low output) pattern, there were 60 (69.8%) cases of deepening of the S wave and 101 (64.3%) cases showing a newly emerged S wave. From the NSLBBP lower output to the SLBBP pattern, there were 171 (85.1%) cases with a deepening S wave and 37 (88.1%) cases with a newly emerged S wave. Sensitivity and specificity of the S wave in lead V6 were 97.9% and 100% in SLBBP, respectively. CONCLUSIONS: The dynamically changing S wave in lead V6 serves as a novel visual indicator of left bundle branch capture.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Cardiology, Ningbo No. 2 Hospital, Ningbo, Zhejiang, China.
- Department of Cardiology, Ningbo No. 2 Hospital, Ningbo, Zhejiang, China. Electronic address: longfujianghwamei@163.com.
Förderung
- Ningbo Science and Technology Bureau
- Medical Scientific Research Foundation of Zhejiang Province, China
Zitieren
APA
Zhuo, S., Jiang, L., Cai, X., Wu, H., Shen, J., Zheng, N., & Sun, W. (2025). Dynamic Changes of the S Wave in Lead V6: A Novel Visual Indicator for Left Bundle Branch Capture. Canadian Journal of Cardiology, 41(12), 2592-2600. https://doi.org/10.1016/j.cjca.2025.08.351
Vancouver
Zhuo S, Jiang L, Cai X, Wu H, Shen J, Zheng N, et al. Dynamic Changes of the S Wave in Lead V6: A Novel Visual Indicator for Left Bundle Branch Capture. Canadian Journal of Cardiology. 2025;41(12):2592-2600. doi:10.1016/j.cjca.2025.08.351
BibTeX
@article{Zhuo2025,
author = {Zhuo, Shanshan and Jiang, Longfu and Cai, Xiaojie and Wu, Hao and Shen, Jiabo and Zheng, Nan and Sun, Weifeng},
title = {Dynamic Changes of the S Wave in Lead V6: A Novel Visual Indicator for Left Bundle Branch Capture},
journal = {Canadian Journal of Cardiology},
year = {2025},
volume = {41},
number = {12},
pages = {2592--2600},
doi = {10.1016/j.cjca.2025.08.351}
}
EUVIMED