Impedance changes during intracardiac echocardiography-confirmed catheter contact in pulsed field ablation

Kohki Kimura, Hirotoshi Nagae, Yuki Yamamoto, Toka Hamaguchi, Masayuki Shiba, Tetsuya Haruna

Indian Pacing and Electrophysiology Journal · 2026-09 · 26 (5) · 485-491

DOI: 10.1016/j.ipej.2026.09.002 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Indian Pacing and Electrophysiology Journal, 2026-09. Verfasst von Kohki Kimura und 5 weiteren Autor:innen. Beteiligte Einrichtung: Cardiovascular Center, Medical Research Institute Kitano Hospital, 2-4-20, Ogimachi, Kitaku, Osaka City, Osaka, 530-8480, Japan. Electronic address: …. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 17 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

PURPOSE: Pulsed field ablation (PFA) has become an established treatment modality for atrial fibrillation (AF). Adequate catheter-to-tissue contact is essential for effective energy delivery. However, impedance characteristics associated with directly visualized catheter contact during PFA have not been well characterized. We evaluated impedance changes measured by the Contact Index during intracardiac echocardiography (ICE)-confirmed catheter contact. METHODS: We retrospectively analyzed 30 consecutive patients who underwent index PFA for AF using a pentaspline catheter under a novel impedance measurement system (EnSite X, Abbott). Impedance changes in each pulmonary vein (PV) using both basket and flower configurations were measured. Catheter-to-tissue contact was confirmed by ICE positioned within the left atrium, and impedance changes associated with ICE-confirmed catheter contact were analyzed. RESULTS: A total of 2400 impedance measurements were analyzed. Median impedance changes ranged from 22% to 25% across pulmonary veins. Linear mixed-effects analysis demonstrated that both pulmonary vein location (P < 0.001) and catheter configuration (P < 0.001) were independently associated with impedance change, whereas no significant interaction was observed between pulmonary vein location and catheter configuration (P = 0.084). CONCLUSIONS: This study characterizes the distribution of impedance changes observed during ICE-confirmed catheter contact across different pulmonary veins and catheter configurations. These findings provide device-specific descriptive reference data for future prospective validation studies.

Schlagwörter

Stichwörter der Autor:innen

Atrial fibrillationCatheter contactImpedanceIntracardiac echocardiographyLeft atriumPulsed field ablation

Autor:innen und Institutionen

  • Cardiovascular Center, Medical Research Institute Kitano Hospital, 2-4-20, Ogimachi, Kitaku, Osaka City, Osaka, 530-8480, Japan. Electronic address: k.kimura.medical@gmail.com.
  • Cardiovascular Center, Medical Research Institute Kitano Hospital, 2-4-20, Ogimachi, Kitaku, Osaka City, Osaka, 530-8480, Japan.

Zitieren

APA

Kimura, K., Nagae, H., Yamamoto, Y., Hamaguchi, T., Shiba, M., & Haruna, T. (2026). Impedance changes during intracardiac echocardiography-confirmed catheter contact in pulsed field ablation. Indian Pacing and Electrophysiology Journal, 26(5), 485-491. https://doi.org/10.1016/j.ipej.2026.09.002

Vancouver

Kimura K, Nagae H, Yamamoto Y, Hamaguchi T, Shiba M, Haruna T. Impedance changes during intracardiac echocardiography-confirmed catheter contact in pulsed field ablation. Indian Pacing and Electrophysiology Journal. 2026;26(5):485-491. doi:10.1016/j.ipej.2026.09.002

BibTeX
@article{Kimura2026,
  author = {Kimura, Kohki and Nagae, Hirotoshi and Yamamoto, Yuki and Hamaguchi, Toka and Shiba, Masayuki and Haruna, Tetsuya},
  title = {Impedance changes during intracardiac echocardiography-confirmed catheter contact in pulsed field ablation},
  journal = {Indian Pacing and Electrophysiology Journal},
  year = {2026},
  volume = {26},
  number = {5},
  pages = {485--491},
  doi = {10.1016/j.ipej.2026.09.002}
}
Kostenlos starten →