Estimation of heart dose in left breast cancer radiotherapy: Assessment of vDIBH feasibility using the supervised machine learning algorithm
Journal of Applied Clinical Medical Physics · 2025
DOI: 10.1002/acm2.14595 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Applied Clinical Medical Physics, 2025. Verfasst von Shriram Ashok Rajurkar und 2 weiteren Autor:innen. Beteiligte Einrichtung: DHR-ICMR JRF, Department of Radiation Oncology, KGMU, Lucknow, Uttar Pradesh, India. Hauptthemen laut MEDLINE: Radiotherapy Planning, Computer-Assisted, Breath Holding, Organs at Risk, Heart. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 32 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Background and objective The volunteer deep inspiration breath hold (vDIBH) technique is used to reduce the heart dose in left breast cancer radiotherapy. Many times, it is faced that despite rigorous exercise and training, not all patients get benefited as expected. The primary objective of this study was to develop a machine learning program for prediction of mean heart dose before left breast radiotherapy under vDIBH.
Methods
The present work is based on the dosimetric parameters of eighty‐two left breast cancer patients, who have undergone modified radical mastectomy, enrolled for their radiation treatment. The trained machine learning algorithm employed linear regression to establish a correlation between Haller Index and heart mean dose (HMD) received during the ca left breast cancer radiotherapy. Subsequently, HMD values were used to model the regression relationship with maximum heart distance (MHD).
Results
The method adopted is beneficial in patient selection and assessment for suitability of patients’ radiotherapy planning under vDIBH treatment technique. For data from 21 test patients, the mean of HMD obtained from the treatment planning system (TPS) and the mean of predicted HMD by developed program were found to be 468.76 cGy and 464.66 cGy, respectively.
Conclusion
The present work facilitates precise HMD prediction in left breast cancer radiation therapy even before starting the treatment planning process. Additionally, this program offers suggestions in terms of modifications in treatment settings for even better results of vDIBH techniques if not matches with the anticipated results.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- DHR-ICMR JRF, Department of Radiation Oncology, KGMU, Lucknow, Uttar Pradesh, India.
- Department of Radiation Oncology, KGMU, Lucknow, Uttar Pradesh, India.
Zitieren
APA
Rajurkar, S. A., Verma, T., & Gupta, R. (2025). Estimation of heart dose in left breast cancer radiotherapy: Assessment of vDIBH feasibility using the supervised machine learning algorithm. Journal of Applied Clinical Medical Physics. https://doi.org/10.1002/acm2.14595
Vancouver
Rajurkar SA, Verma T, Gupta R. Estimation of heart dose in left breast cancer radiotherapy: Assessment of vDIBH feasibility using the supervised machine learning algorithm. Journal of Applied Clinical Medical Physics. 2025. doi:10.1002/acm2.14595
BibTeX
@article{Rajurkar2025,
author = {Rajurkar, Shriram Ashok and Verma, Teerthraj and Gupta, Rajeev},
title = {Estimation of heart dose in left breast cancer radiotherapy: Assessment of vDIBH feasibility using the supervised machine learning algorithm},
journal = {Journal of Applied Clinical Medical Physics},
year = {2025},
doi = {10.1002/acm2.14595}
}
EUVIMED