EUVIMEDEUVIMED entdecken
VergleichsstudieStudienprotokollOpen Access · CC BY-NC-ND 4.0

Fluoroless high-density pulsed field vs radiofrequency ablation for atrial fibrillation guided by left atrial intracardiac echocardiography: The HALO protocol

Guilherme Pontes Saad, Charles Slater, Jessica Araujo Fernandes, Gustavo Vignoli Dos Santos, Luiz Antonio Oliveira, Eduardo Benchimol Saad

Heart Rhythm · 2026

DOI: 10.1016/j.hrthm.2026.06.011 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Heart Rhythm, 2026. Verfasst von Guilherme Pontes Saad und 5 weiteren Autor:innen. Beteiligte Einrichtung: College of Engineering, Department of Biomedical Engineering, University of Miami, Coral Gables, FL. Electronic address: eduardobsaad@hotmail.com. Hauptthemen laut MEDLINE: Atrial Fibrillation, Catheter Ablation, Heart Atria, Echocardiography. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 35 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Pulsed field ablation (PFA) is an alternative energy source to radiofrequency ablation (RFA) for atrial fibrillation (AF) with favorable safety and efficiency; however, outcomes are dependent on technique, lesion density, and tissue-contact assessment. OBJECTIVE: This study aimed to compare outcomes of AF ablation using PFA vs RFA when performed in an identical fluoroless workflow incorporating electroanatomic mapping and intracardiac echocardiography (ICE) using the high-density antral left atrial (LA) ICE-guided overlapping protocol. METHODS: This was a retrospective analysis of 192 patients undergoing AF ablation guided by LA ICE for contact assessment. PFA (n = 62) used high-density antral pulmonary vein overlapping lesions, whereas RFA (n = 130) combined ICE tissue enhancement with contact-force guidance. Lesion delivery was guided by spatial density and contact quality. RESULTS: Mean follow-up was 10.6 ± 4.3 months. Arrhythmia recurrence was lower with PFA (4.8%) than RFA (13.1%; 95% confidence interval, 0.09-1.15; P = .082). In paroxysmal AF, recurrence was significantly lower with PFA (2.1%) than RFA (15.8%; 95% confidence interval, 0.01-0.83; P = .011). In persistent AF, recurrence rates were similar (P = .569) despite a 3.5-fold higher proportion of redo procedures in the RFA group (P = .001) and more frequent posterior wall isolation in the PFA group (46.8% vs 20.8%; P < .001). Procedure duration was significantly shorter with PFA. No major complications occurred. CONCLUSION: In a standardized fluoroless high-density antral LA ICE-guided overlapping workflow, PFA achieved better short-term rhythm control in paroxysmal AF and significantly shorter procedure times. In persistent AF, outcomes were comparable with RFA. Lesion strategy and quality are critical determinants of ablation success beyond energy source selection alone.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Atrial FibrillationCatheter AblationHeart AtriaEchocardiographySurgery, Computer-AssistedHumansRetrospective StudiesFemaleMaleTreatment OutcomeMiddle AgedFollow-Up StudiesPulmonary Veins

Stichwörter der Autor:innen

Atrial fibrillationFluoroless ablationHigh-density lesionsIntracardiac echocardiographyLesion durabilityPulmonary vein isolationPulsed field ablationRadiofrequency ablation

Autor:innen und Institutionen

  • College of Engineering, Department of Biomedical Engineering, University of Miami, Coral Gables, FL. Electronic address: eduardobsaad@hotmail.com.
  • Center for Atrial Fibrillation, Cardiac Arrhythmia Service, Hospital Samaritano Botafogo, Rio de Janeiro, Brazil.

Zitieren

APA

Saad, G. P., Slater, C., Fernandes, J. A., Vignoli Dos Santos, G., Oliveira, L. A., & Saad, E. B. (2026). Fluoroless high-density pulsed field vs radiofrequency ablation for atrial fibrillation guided by left atrial intracardiac echocardiography: The HALO protocol. Heart Rhythm. https://doi.org/10.1016/j.hrthm.2026.06.011

Vancouver

Saad GP, Slater C, Fernandes JA, Vignoli Dos Santos G, Oliveira LA, Saad EB. Fluoroless high-density pulsed field vs radiofrequency ablation for atrial fibrillation guided by left atrial intracardiac echocardiography: The HALO protocol. Heart Rhythm. 2026. doi:10.1016/j.hrthm.2026.06.011

BibTeX
@article{Saad2026,
  author = {Saad, Guilherme Pontes and Slater, Charles and Fernandes, Jessica Araujo and Vignoli Dos Santos, Gustavo and Oliveira, Luiz Antonio and Saad, Eduardo Benchimol},
  title = {Fluoroless high-density pulsed field vs radiofrequency ablation for atrial fibrillation guided by left atrial intracardiac echocardiography: The HALO protocol},
  journal = {Heart Rhythm},
  year = {2026},
  doi = {10.1016/j.hrthm.2026.06.011}
}
Kostenlos starten →