EUVIMEDEUVIMED entdecken
Beobachtungsstudie

Residual tiny pulmonary vein potentials on high-resolution mapping after pulsed field ablation predict atrial arrhythmia recurrence and poor durability of pulmonary vein isolation

Masaharu Masuda, Takashi Sumigawa, Hiroyuki Uematsu, Shota Kato, Hirotaka Ooka, Satoshi Kudo, Mizuki Ochi, Shin Okamoto, Takayuki Ishihara, Kiyonori Nanto, Yosuke Hata, Sho Nakao und 6 weitere

Heart Rhythm · 2026

DOI: 10.1016/j.hrthm.2026.04.047 ↗

Kurz gefasst

Beobachtungsstudie in der Zeitschrift Heart Rhythm, 2026. Verfasst von Masaharu Masuda und 17 weiteren Autor:innen. Beteiligte Einrichtung: Kansai Rosai Hospital Cardiovascular Center, Amagasaki, Hyogo, Japan. Electronic address: masuda-masaharu@kansaih.johas.go.jp. Hauptthemen laut MEDLINE: Pulmonary Veins, Atrial Fibrillation, Catheter Ablation, Heart Conduction System. Die Arbeit nennt 14 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Pulsed field ablation (PFA) enables safe and efficient achievement of acute pulmonary vein (PV) isolation, with apparent elimination of PV potentials (PVPs) as assessed by the relatively coarse electrogram evaluation using single-shot PFA ablation catheters. Nevertheless, late-phase left atrium (LA)-PV reconnection remains a clinically relevant issue. OBJECTIVE: This study aimed to elucidate the potential role of residual tiny PVPs observed on high-resolution mapping after the elimination of overt PVPs by single-shot PFA for the prediction of atrial arrhythmia recurrence and late-phase LA-PV reconnection. METHODS: This retrospective observational study included patients who underwent an initial ablation for atrial fibrillation (AF) using a single-shot PFA device and were evaluated with high-resolution mapping immediately after ablation. Residual tiny PVPs were defined as low-amplitude electrograms with a bipolar voltage of ≥0.03 mV. Patients were followed for 1 year to assess AF or atrial tachycardia (AT) recurrence. In patients undergoing repeat ablation for recurrent atrial arrhythmias, the spatial relationship between residual tiny PVPs was identified at the initial ablation and late-phase LA-PV reconnection. RESULTS: Among 158 patients, residual tiny PVPs were identified in 48 (30%). The presence of residual tiny PVPs was significantly associated with AF/AT recurrence during 1-year follow-up (hazard ratio 2.68; 95% confidence interval 1.14-6.31; P = .024). Among 15 patients undergoing repeat ablation, 81% of residual tiny PVP sites showed locational concordance with late-phase LA-PV reconnection. CONCLUSION: Residual tiny PVPs detected by high-resolution mapping after PFA predict 1-year AF/AT recurrence and precede clinically significant LA-PV reconnection.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Pulmonary VeinsAtrial FibrillationCatheter AblationHeart Conduction SystemBody Surface Potential MappingHeart AtriaHumansRetrospective StudiesRecurrenceFemaleMaleFollow-Up StudiesElectrophysiologic Techniques, CardiacMiddle Aged

Stichwörter der Autor:innen

Atrial fibrillationEndpointPulmonary vein isolationPulse field ablationResidual pulmonary vein potential

Autor:innen und Institutionen

  • Kansai Rosai Hospital Cardiovascular Center, Amagasaki, Hyogo, Japan. Electronic address: masuda-masaharu@kansaih.johas.go.jp.
  • Kansai Rosai Hospital Cardiovascular Center, Amagasaki, Hyogo, Japan.

Zitieren

APA

Masuda, M., Sumigawa, T., Uematsu, H., Kato, S., Ooka, H., Kudo, S., Ochi, M., Okamoto, S., Ishihara, T., Nanto, K., Hata, Y., Nakao, S., Kusuda, M., Ariyasu, W., Fujii, S., Miyaguchi, H., Nanri, K., & Mano, T. (2026). Residual tiny pulmonary vein potentials on high-resolution mapping after pulsed field ablation predict atrial arrhythmia recurrence and poor durability of pulmonary vein isolation. Heart Rhythm. https://doi.org/10.1016/j.hrthm.2026.04.047

Vancouver

Masuda M, Sumigawa T, Uematsu H, Kato S, Ooka H, Kudo S, et al. Residual tiny pulmonary vein potentials on high-resolution mapping after pulsed field ablation predict atrial arrhythmia recurrence and poor durability of pulmonary vein isolation. Heart Rhythm. 2026. doi:10.1016/j.hrthm.2026.04.047

BibTeX
@article{Masuda2026,
  author = {Masuda, Masaharu and Sumigawa, Takashi and Uematsu, Hiroyuki and Kato, Shota and Ooka, Hirotaka and Kudo, Satoshi and Ochi, Mizuki and Okamoto, Shin and Ishihara, Takayuki and Nanto, Kiyonori and Hata, Yosuke and Nakao, Sho and Kusuda, Masaya and Ariyasu, Wataru and Fujii, Subaru and Miyaguchi, Haruna and Nanri, Kohei and Mano, Toshiaki},
  title = {Residual tiny pulmonary vein potentials on high-resolution mapping after pulsed field ablation predict atrial arrhythmia recurrence and poor durability of pulmonary vein isolation},
  journal = {Heart Rhythm},
  year = {2026},
  doi = {10.1016/j.hrthm.2026.04.047}
}
Kostenlos starten →