EUVIMEDEUVIMED entdecken
BeobachtungsstudieMultizentrische StudieVergleichsstudie

Pulsed field ablation with a pentaspline catheter and concomitant left atrial appendage closure for long-standing persistent atrial fibrillation: Comparison with a radiofrequency cohort

Marco Schiavone, Vincenzo Mirco La Fazia, Gaetano Fassini, Alessio Gasperetti, Sanghamitra Mohanty, Lorenzo Bianchini, Xiao-Dong Zhang, Massimo Moltrasio, Elio Zito, Marco Marino, Fabrizio Tundo, Giovanni B Forleo und 3 weitere

Heart Rhythm · 2026

DOI: 10.1016/j.hrthm.2026.04.018 ↗

Kurz gefasst

Beobachtungsstudie in der Zeitschrift Heart Rhythm, 2026. Verfasst von Marco Schiavone und 14 weiteren Autor:innen. Beteiligte Einrichtung: Department of Clinical Electrophysiology and Cardiac Pacing, Centro Cardiologico Monzino IRCSS, Milan, Italy. Hauptthemen laut MEDLINE: Atrial Fibrillation, Left Atrial Appendage Closure, Catheter Ablation, Atrial Appendage. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 29 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Pulsed field ablation (PFA) is increasingly being adopted for atrial fibrillation (AF) ablation, but outcome data, when it is combined with left atrial appendage occlusion (LAAO), remain limited. OBJECTIVE: We evaluated outcomes of extensive PFA combined with LAAO, compared with radiofrequency ablation plus LAAO in patients with long-standing persistent AF. METHODS: In this observational, multicenter, propensity-matched study, 90 consecutive patients with drug-refractory, long-standing persistent AF underwent combined ablation (pulmonary veins, posterior wall, and LAA electrical isolation) plus LAAO (45 PFA, 45 RF). Matching was 1:1 based on age, CHA2DS2-VASc score, HAS-BLED score, and LAAO device. Follow-up was censored at 12 months. RESULTS: Baseline characteristics were balanced after matching. Procedural time was shorter with PFA than RF (86.0 ± 6.8 vs 114.5 ± 11.5 minutes, P = 0.042). Acute LAAO success was 100% in both groups, with similar complication rates (1 pericardial effusion each). Overall peri-device leak (PDL) incidence was lower with PFA (8.9% vs 24.4%, P = 0.048), although clinically relevant leaks >3 mm were infrequent and comparable (0% vs 4.4%, P = 0.494). At 12 months, arrhythmic recurrences were numerically lower with PFA (22.2% vs 40.0%, P = 0.069; log-rank P = 0.093). No strokes or major bleeding occurred in the PFA cohort, whereas 1 non-cardioembolic stroke and 2 major bleeding events occurred in the RF group. In Cox regression, only AF duration >18 months predicted recurrence (hazard ratio = 3.27, 95% confidence interval 1.15-9.32; P = 0.027). CONCLUSION: Extensive PFA, including LAA electrical isolation, combined with LAAO was feasible and safe, resulting in shorter procedures, fewer overall PDLs compared with RF but similar rate of PDL >3 mm.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Atrial FibrillationLeft Atrial Appendage ClosureCatheter AblationAtrial AppendageHumansFemaleMaleTreatment OutcomeFollow-Up StudiesAgedPulmonary Veins

Stichwörter der Autor:innen

Atrial fibrillationCatheter ablationLeft atrial appendageOcclusionPulsed field ablation

Autor:innen und Institutionen

  • Department of Clinical Electrophysiology and Cardiac Pacing, Centro Cardiologico Monzino IRCSS, Milan, Italy.
  • Texas Cardiac Arrhythmia Institute, St David's Medical Center, Austin, Texas.
  • Division of Cardiology, Department of Medicine, The Johns Hopkins University School of Medicine, Baltimore, Maryland.
  • Cardiac Arrhythmia Center, Division of Cardiology at Montefiore-Einstein Center, Albert Einstein College of Medicine, Bronx, New York.
  • Cardiology School, University of Milan, Milan, Italy.
  • Division of Cardiology, Tor Vergata University of Rome, Rome, Italy.

Zitieren

APA

Schiavone, M., La Fazia, V. M., Fassini, G., Gasperetti, A., Mohanty, S., Bianchini, L., Zhang, X. D., Moltrasio, M., Zito, E., Marino, M., Tundo, F., Forleo, G. B., di Biase, L., Natale, A., & Tondo, C. (2026). Pulsed field ablation with a pentaspline catheter and concomitant left atrial appendage closure for long-standing persistent atrial fibrillation: Comparison with a radiofrequency cohort. Heart Rhythm. https://doi.org/10.1016/j.hrthm.2026.04.018

Vancouver

Schiavone M, La Fazia VM, Fassini G, Gasperetti A, Mohanty S, Bianchini L, et al. Pulsed field ablation with a pentaspline catheter and concomitant left atrial appendage closure for long-standing persistent atrial fibrillation: Comparison with a radiofrequency cohort. Heart Rhythm. 2026. doi:10.1016/j.hrthm.2026.04.018

BibTeX
@article{Schiavone2026,
  author = {Schiavone, Marco and La Fazia, Vincenzo Mirco and Fassini, Gaetano and Gasperetti, Alessio and Mohanty, Sanghamitra and Bianchini, Lorenzo and Zhang, Xiao-Dong and Moltrasio, Massimo and Zito, Elio and Marino, Marco and Tundo, Fabrizio and Forleo, Giovanni B and di Biase, Luigi and Natale, Andrea and Tondo, Claudio},
  title = {Pulsed field ablation with a pentaspline catheter and concomitant left atrial appendage closure for long-standing persistent atrial fibrillation: Comparison with a radiofrequency cohort},
  journal = {Heart Rhythm},
  year = {2026},
  doi = {10.1016/j.hrthm.2026.04.018}
}
Kostenlos starten →