Burden-based outcomes after atrial fibrillation ablation: A 4-year continuous monitoring study
Heart Rhythm · 2026
DOI: 10.1016/j.hrthm.2026.01.017 ↗Kurz gefasst
Fachartikel in der Zeitschrift Heart Rhythm, 2026. Verfasst von Alexandre Almorad und 9 weiteren Autor:innen. Beteiligte Einrichtung: Heart Rhythm Management Centre, Universitair Ziekenhuis Brussel, Heart Rhythm Research Brussels, Postgraduate Program in Cardiac Electrophysiology an…. Hauptthemen laut MEDLINE: Atrial Fibrillation, Catheter Ablation, Quality of Life, Electrocardiography, Ambulatory. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 48 Literaturangaben.
Abstract (Originalsprache)
BACKGROUND: Atrial fibrillation (AF) markedly impairs quality of life (QoL) and increases health care burden. Long-term outcomes of catheter ablation (CA) using continuous rhythm monitoring remain undercharacterized. OBJECTIVES: The goals of this study were to assess atrial tachyarrhythmia burden (ATaB) using implantable loop recorder (ILRs) before and up to 4 years after CA and to examine the association between ATaB reduction and QoL. In an exploratory proof-of-concept analysis, we evaluated whether simulated intermittent monitoring (burden-by-sampling [BBS]) can approximate ILR-derived ATaB. METHODS: In this single-center prospective cohort, 165 patients with paroxysmal or persistent AF underwent first-time CA after preablation ILR insertion. ATaB (percentage time in AF/atrial tachycardia) was continuously recorded for up to 4 years. Annual QoL assessments used the Short Form-36 Health Survey and an AF-specific symptom questionnaire. Retrospective BBS simulation sampled ILR data at varying frequencies to explore intermittent monitoring performance. RESULTS: The median follow-up period was 40.9 (38.3-42.8) months. The median ATaB declined from 15% (0%-100%) to 0% (0%-22.5%) (P 90% of patients achieved ≥75% reduction. QoL improved significantly at 1 year and remained stable, although Short Form-36 Health Survey physical health scores were not consistently significant beyond 1 year. BBS performance improved with increased sampling frequency but remained exploratory. CONCLUSION: CA produces a durable, substantial reduction in ATaB over 4 years, with a sustained QoL benefit. These findings challenge binary definitions of ablation success and support burden-based, patient-centered end points. Exploratory BBS simulations suggest potential for intermittent monitoring but require prospective validation.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Heart Rhythm Management Centre, Universitair Ziekenhuis Brussel, Heart Rhythm Research Brussels, Postgraduate Program in Cardiac Electrophysiology and Pacing, Vrije Universiteit Brussel, European Reference Networks Guar…
- Department of Cardiology, Sint-Jan Hospital Bruges, Bruges, Belgium.
- Independent Researcher, Brussels, Belgium.
- Department of Cardiology, Sint-Jan Hospital Bruges, Bruges, Belgium. Electronic address: Sebastien.Knecht@azsintjan.be.
Zitieren
APA
Almorad, A., El Haddad, M., El Channan, M., Blankoff, N., Hossein, A., Amin, R., de Waroux, J. L. P., Tavernier, R., Duytschaever, M., & Knecht, S. (2026). Burden-based outcomes after atrial fibrillation ablation: A 4-year continuous monitoring study. Heart Rhythm. https://doi.org/10.1016/j.hrthm.2026.01.017
Vancouver
Almorad A, El Haddad M, El Channan M, Blankoff N, Hossein A, Amin R, et al. Burden-based outcomes after atrial fibrillation ablation: A 4-year continuous monitoring study. Heart Rhythm. 2026. doi:10.1016/j.hrthm.2026.01.017
BibTeX
@article{Almorad2026,
author = {Almorad, Alexandre and El Haddad, Milad and El Channan, Mehdi and Blankoff, Nicolas and Hossein, Amin and Amin, Reshma and de Waroux, Jean-Benoît le Polain and Tavernier, René and Duytschaever, Mattias and Knecht, Sébastien},
title = {Burden-based outcomes after atrial fibrillation ablation: A 4-year continuous monitoring study},
journal = {Heart Rhythm},
year = {2026},
doi = {10.1016/j.hrthm.2026.01.017}
}
EUVIMED