EUVIMEDEUVIMED entdecken
Crossref

Real-time smartphone alerts during atrial fibrillation episodes with implantable cardiac monitors and wearable devices: SMART-ALERT study

Andre Briosa E Gala, Alexander James Sharp, Michael Timothy Brian Pope, Milena Leo, Richard Varini, John Paisey, Nick Curzen, Abhirup Banerjee, Timothy Rider Betts

Heart Rhythm · 2026-04 · 23 (4) · 807-818

DOI: 10.1016/j.hrthm.2025.04.015 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Heart Rhythm, 2026-04. Verfasst von Andre Briosa E Gala und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiology, Oxford University Hospitals NHS Foundation Trust, Oxford, United Kingdom; Faculty of Medicine, University of Southampton, S…. Hauptthemen laut MEDLINE: Atrial Fibrillation, Smartphone, Wearable Electronic Devices, Electrocardiography, Ambulatory. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 28 Literaturangaben. Gefördert von: Royal Society, Heart Research UK.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Atrial fibrillation (AF) is a major cause of stroke, with dynamic thromboembolic risk during and shortly after episodes. Implantable cardiac monitors and wearable devices have emerged as tools for real-time AF detection, yet their comparative performance in supporting anticoagulation strategies remains underexplored. OBJECTIVE: This single-center feasibility study investigated the performance of real-time AF detection and notification for episodes lasting longer than 30 minutes. METHODS: Phase 1 evaluated the integration of an implantable cardiac monitor and bespoke cloud-based software (SMART-ALERT) in sending automated short message service notifications (n = 50) for episodes uploaded within 24 hours. Phase 2 evaluated the Apple Watch (n = 23) and the CART Ring (n = 23) detecting and notifying participants of AF episodes. The primary outcome was the successful AF notification rates via (1) SMART-ALERT software and (2) wearable devices. Secondary outcomes included acknowledgment rates, notification times, and adherence. RESULT: Among 4943 AF episodes detected in 31 participants, the SMART-ALERT software successfully notified 511 of 691 eligible AF episodes (74%), with a 99.6% acknowledgment. In contrast, wearable devices showed poor notification performance: the Apple Watch identified 76 of 389 episodes (19.5%); and the CART Ring, 72 of 474 (15.1%). This performance difference was partly explained by suboptimal device adherence (Apple Watch: 66.3%; CART Ring: 23.9%), with 24.6% and 55.7% of AF episodes missed because of devices not being worn. CONCLUSION: The SMART-ALERT system demonstrated the feasibility of real-time AF detection and automated notifications, achieving a 74% notification success but facing important connectivity challenges. Wearable devices showed poor notification rates (

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Atrial FibrillationSmartphoneWearable Electronic DevicesElectrocardiography, AmbulatoryHumansMaleFemaleAgedFeasibility StudiesMiddle Aged

Stichwörter der Autor:innen

AnticoagulationApple WatchAtrial fibrillationCART RingWearable devices

Autor:innen und Institutionen

  • Department of Cardiology, Oxford University Hospitals NHS Foundation Trust, Oxford, United Kingdom; Faculty of Medicine, University of Southampton, Southampton, United Kingdom; Wessex Cardiac Unit, University Hospital S…
  • Department of Cardiology, Oxford University Hospitals NHS Foundation Trust, Oxford, United Kingdom; Institute of Biomedical Engineering, Department of Engineering Science, University of Oxford, Oxford, United Kingdom.
  • Wessex Cardiac Unit, University Hospital Southampton NHS Foundation Trust, Southampton, United Kingdom.
  • Queen Alexandra Hospital, Portsmouth, United Kingdom.
  • Department of Cardiology, Oxford University Hospitals NHS Foundation Trust, Oxford, United Kingdom.
  • Faculty of Medicine, University of Southampton, Southampton, United Kingdom; Wessex Cardiac Unit, University Hospital Southampton NHS Foundation Trust, Southampton, United Kingdom.

Förderung

  • Royal Society
  • Heart Research UK

Zitieren

APA

Briosa E Gala, A., Sharp, A. J., Pope, M. T. B., Leo, M., Varini, R., Paisey, J., Curzen, N., Banerjee, A., & Betts, T. R. (2026). Real-time smartphone alerts during atrial fibrillation episodes with implantable cardiac monitors and wearable devices: SMART-ALERT study. Heart Rhythm, 23(4), 807-818. https://doi.org/10.1016/j.hrthm.2025.04.015

Vancouver

Briosa E Gala A, Sharp AJ, Pope MTB, Leo M, Varini R, Paisey J, et al. Real-time smartphone alerts during atrial fibrillation episodes with implantable cardiac monitors and wearable devices: SMART-ALERT study. Heart Rhythm. 2026;23(4):807-818. doi:10.1016/j.hrthm.2025.04.015

BibTeX
@article{BriosaEGala2026,
  author = {Briosa E Gala, Andre and Sharp, Alexander James and Pope, Michael Timothy Brian and Leo, Milena and Varini, Richard and Paisey, John and Curzen, Nick and Banerjee, Abhirup and Betts, Timothy Rider},
  title = {Real-time smartphone alerts during atrial fibrillation episodes with implantable cardiac monitors and wearable devices: SMART-ALERT study},
  journal = {Heart Rhythm},
  year = {2026},
  volume = {23},
  number = {4},
  pages = {807--818},
  doi = {10.1016/j.hrthm.2025.04.015}
}