Quantifying pulmonary vein antrum contact area with novel dual-sized cryoballoon to optimize pulmonary vein isolation
Heart Rhythm · 2024-11 · 21 (11) · 2360-2361
DOI: 10.1016/j.hrthm.2024.05.047 ↗Kurz gefasst
Fachartikel in der Zeitschrift Heart Rhythm, 2024-11. Verfasst von Yu Liao und 9 weiteren Autor:innen. Beteiligte Einrichtung: Banner University Medical Center-Phoenix, University of Arizona, College of Medicine, Phoenix, Arizona; National Cheng Kung University Hospital, Tain…. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 3 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Boston Scientific Corporation.
Abstract (Originalsprache)
Effective pulmonary vein isolation (PVI) for the treatment of atrial fibrillation (AF) requires complete pulmonary vein (PV) occlusion with tight, large-area cryoballoon–PV antrum contact to achieve transmural and durable cryolesions.1 Clinical studies have demonstrated the feasibility, efficacy, and safety of the POLARx FIT cryoablation system (Boston Scientific, Minneapolis, MN) featuring an expandable and compliant cryoballoon that enables 2 balloon sizes, 28 mm and 31mm, in one catheter.2 Using geometric models, we aimed to correlate differences in ablation area to the intraprocedural performance of the POLARx FIT cryoballoon.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Banner University Medical Center-Phoenix, University of Arizona, College of Medicine, Phoenix, Arizona; National Cheng Kung University Hospital, Tainan, Taiwan.
- Banner University Medical Center-Phoenix, University of Arizona, College of Medicine, Phoenix, Arizona. Electronic address: bairong74@gmail.com.
- Boston Scientific Corporation-Cardiology, St Paul, Minnesota.
- Banner University Medical Center-Phoenix, University of Arizona, College of Medicine, Phoenix, Arizona.
Förderung
- Boston Scientific Corporation
Zitieren
APA
Liao, Y., Bai, R., Murthy, S., Smith, D. J., Ebady, R., Shatz, D. Y., Weiss, J. P., Zawaneh, M., Tung, R., & Su, W. (2024). Quantifying pulmonary vein antrum contact area with novel dual-sized cryoballoon to optimize pulmonary vein isolation. Heart Rhythm, 21(11), 2360-2361. https://doi.org/10.1016/j.hrthm.2024.05.047
Vancouver
Liao Y, Bai R, Murthy S, Smith DJ, Ebady R, Shatz DY, et al. Quantifying pulmonary vein antrum contact area with novel dual-sized cryoballoon to optimize pulmonary vein isolation. Heart Rhythm. 2024;21(11):2360-2361. doi:10.1016/j.hrthm.2024.05.047
BibTeX
@article{Liao2024,
author = {Liao, Yu and Bai, Rong and Murthy, Sam and Smith, David J and Ebady, Rhodaba and Shatz, Dalise Yi and Weiss, J Peter and Zawaneh, Michael and Tung, Roderick and Su, Wilber},
title = {Quantifying pulmonary vein antrum contact area with novel dual-sized cryoballoon to optimize pulmonary vein isolation},
journal = {Heart Rhythm},
year = {2024},
volume = {21},
number = {11},
pages = {2360--2361},
doi = {10.1016/j.hrthm.2024.05.047}
}
EUVIMED